An innovative, simple, accurate, sensitive, and eco-friendly synchronous fluorescence spectrofluorimetric method has been developed for the simultaneous analysis of montelukast sodium (MON) and fexofenadine hydrochloride (FEX). The method relies on measuring the relative synchronous fluorescence intensity of both drugs using Δλ of 60 nm in methanol at 405 nm for MON and 288 nm for FEX. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.1-2.0 and 2.0-20.0 μg/ml for MON and FEX, respectively. The limits of detection were 0.018 and 0.441 μg/ml, and the limits of quantitation were 0.055 and 1.336 μg/ml for MON and FEX, respectively. The developed method was applied successfully for the determination of the two drugs in their newly released fixed-dose combination prescribed for the treatment of allergic rhinitis. The mean per cent recoveries were found to be 100.680 ± 0.890 and 100.110 ± 0.940 for MON and FEX, respectively. Furthermore, the method was found to be eco-friendly green as was evaluated according to the Green Analytical Procedure Index tool guidelines and analytical eco-scale.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bio.4648DOI Listing

Publication Analysis

Top Keywords

synchronous fluorescence
12
mon fex
12
eco-friendly synchronous
8
fluorescence spectrofluorimetric
8
spectrofluorimetric method
8
montelukast sodium
8
fexofenadine hydrochloride
8
fixed-dose combination
8
fex method
8
developed method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!