A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

No difference in patient reported outcome and inflammatory response after coated and uncoated total knee arthroplasty - a randomized controlled study. | LitMetric

Background: Allergies against implant materials are still not fully understood. Despite controversies about its relevance, some patients need treatment with hypoallergenic implants. This study compared coated and standard total knee arthroplasty (TKA) regarding inflammatory response and patient-reported outcome measures (PROMs).

Methods: 76 patients without self-reported allergies against implant materials were included in a RCT and received a coated or standard TKA of the same cemented posterior-stabilized knee system. 73 patients completed the 3-year follow-up. Two patients died and there was one revision surgery. Serum levels of cytokines with a possible role in implant allergy were measured in patient`s serum (IL-1beta, IL-5, IL-6, IL-8, IL-10, IFN γ, TNF α) prior to, one and three years after surgery. Furthermore, PROMs including knee function (Oxford Knee Score, Knee Society Score) and health-related quality of life (QoL, EuroQuol questionnaire) were assessed. Additionally, 8 patients with patch-test proven skin allergy against implant materials who received the coated implant were assessed similarly and compared to a matched-pair group receiving the same implant.

Results: There were no differences in function and QoL between the assessed groups at any follow-up. The majority of patients demonstrated no elevation of the measured blood cytokines. Cytokine patterns showed no differences between study groups at any follow-up. The allergy patients demonstrated slower functional improvement and minor differences in cytokine pattern. Yet these results were not significant. There were no differences in the matched-pair analysis.

Conclusion: We observed no relevant increase in serum cytokine levels in any group. The inflammatory response measured seems limited, even in allergy patients. Furthermore, there were no differences between coated and standard TKA in non-allergy patients in the 3-year Follow-Up period.

Trial Registration: The study protocol was registered in the US National Institutes of Health's database ( http://www.

Clinicaltrials: gov ) registry under NCT03424174 on 03/17/2016.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10720193PMC
http://dx.doi.org/10.1186/s12891-023-07061-xDOI Listing

Publication Analysis

Top Keywords

inflammatory response
12
implant materials
12
coated standard
12
patients
9
total knee
8
knee arthroplasty
8
allergies implant
8
received coated
8
standard tka
8
3-year follow-up
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!