Modeling the Relationship Between Diastolic Phenotype and Outcomes in Pediatric Hypertrophic Cardiomyopathy.

J Am Soc Echocardiogr

Division of Cardiology, Department of Paediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada.

Published: May 2024

Background: Pediatric hypertrophic cardiomyopathy (HCM) is associated with adverse events. The contribution of diastolic dysfunction to adverse events is poorly understood. The aim of this study was to explore the association between diastolic phenotype and outcomes in pediatric patients with HCM.

Methods: Children <18 years of age with diagnosed with HCM were included. Diastolic function parameters were measured from the first echocardiogram at the time of diagnosis, including Doppler flow velocities, tissue Doppler velocities, and left atrial volume and function. Using principal-component analysis, key features in echocardiographic parameters were identified. The principal components were regressed to freedom from major adverse cardiac events (MACE), defined as implantable cardioverter-defibrillator insertion, myectomy, aborted sudden cardiac death, transplantation, need for mechanical circulatory support, and death.

Results: Variables that estimate left ventricular filling pressures were highly collinear and associated with MACE (hazard ratio, 0.86; 95% CI, 0.75-1.00), though this was no longer significant after controlling for left ventricular thickness and genetic variation. Left atrial size parameters adjusted for body surface area were independently associated with outcomes in the covariate-adjusted model (hazard ratio, 0.69; 95% CI, 0.5-0.94). The covariate-adjusted model had an Akaike information criterion of 213, an adjusted R value of 0.78, and a concordance index of 0.82 for association with MACE.

Conclusion: Echocardiographic parameters of diastolic dysfunction were associated with MACE in this population study, in combination with the severity of left ventricular hypertrophy and genetic variation. Left atrial size parameters adjusted for body surface area were independently associated with adverse events. Additional study of diastolic function parameters adjusted for patient size could facilitate the prediction of adverse events in pediatric patients with HCM.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2023.11.025DOI Listing

Publication Analysis

Top Keywords

diastolic phenotype
8
phenotype outcomes
8
outcomes pediatric
8
pediatric hypertrophic
8
hypertrophic cardiomyopathy
8
adverse events
8
modeling relationship
4
relationship diastolic
4
cardiomyopathy background
4
background pediatric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!