Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The morphological assessment of the pubic symphysis using the Suchey-Brooks method is considered a reliable age at death indicator. Age at death estimation methods can be adapted to the images obtained from post-mortem computed tomography (PMCT). The aim of this study is to evaluate the utility of pubic symphysis photorealistic images obtained through Global illumination rendering (GIR) for age at death estimation from whole-body PMCT and from focused PMCT on the pubic bone.
Materials And Methods: We performed virtual age at death estimation using the Suchey Brooks method from both the whole-body field of view (Large Field of View: LFOV) and the pubis-focused field of view (Small and Field of View: SFOV) of 100 PMCT. The 3D photorealistic images were evaluated by three forensic anthropologists and the results were statistically evaluated for accuracy of the two applied PMCT methods and the intra- and inter-observer errors.
Results: When comparing the two acquisitions of PMCT, the accuracy rate reaches 98.5% when using a pubic-focused window (SFOV) compared to 86% with a whole-body window (LFOV). Additionally, the intra- and inter-observer variability has demonstrated that the focused window provides better repeatability and reproducibility.
Conclusion: Adding a pubic-focused field of view to standard PMCT and processing it with GIR appears to be an applicable technique that increases the accuracy rate for age at death estimation from the pubic symphysis.