Impact of thermal desorption tubes on the variability of exhaled breath data.

J Breath Res

Air Force Research Laboratory, 711th Human Performance Wing/RHBBA, 2510 Fifth Street, Area B, Building 840, Wright- Patterson AFB, OH 45433, United States of America.

Published: December 2023

Due to the overall low abundance of volatile compounds in exhaled breath, it is necessary to preconcentrate the sample prior to traditional thermal desorption (TD) gas chromatography mass spectrometry analysis. While certain aspects of TD tubes, such as volatile storage, have been evaluated, many aspects remain uncharacterized. Two common TD tubes, Tenax TA and Biomonitoring 5TD tubes, were evaluated for background content and flow rate variability. The data illustrate that the Biomonitoring 5TD tubes have the highest number (23) and abundance of background contamination greater than 3x the mean noise when compared to Tenax TA (13) and empty tubes (9). Tentative identifications of the compounds in the background contamination experiment show that greater than 59% (16/27) of the compounds identified have been reported in the breath literature. The data illustrate the TD tube background abundance could account for more than 70% of the chromatographic signal from exhaled breath for these select compounds. Flow rate measurements of 200 Tenax TA and 200 Biomonitoring 5TD tubes show a large range in measured flow rates among the TD tubes (Tenax: 252.9-284.0 ml min, 5TD: 220.6-255.1 ml min). Finally, TD tubes of each type, Tenax TA and Biomonitoring 5TD, previously established to have high, medium, and low flow rates, show insignificant differences (> 0.05) among the tubes of different flow rates, using both gas standards and an exhaled breath from a peppermint experiment. Collectively, these results establish overall background compounds attributed to each TD tube type tested. Additionally, while measured flow rate variability is present and plausibly impacts exhaled breath results, the data demonstrate no statistically significant difference was observed between tubes showing high, medium, and low flow rates from two separate sample types.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1752-7163/ad15a3DOI Listing

Publication Analysis

Top Keywords

exhaled breath
20
biomonitoring 5td
16
flow rates
16
5td tubes
12
flow rate
12
tubes
11
thermal desorption
8
breath data
8
tubes tenax
8
tenax biomonitoring
8

Similar Publications

Introduction: Elexacaftor/tezacaftor/ivacaftor (ETI) has shown significant improvements in pulmonary and nutritional status in persons with cystic fibrosis (pwCF). Less is known about the extrapulmonary impact of ETI and effects on airway microbiology, lung clearance index (LCI) and fraction of exhaled nitric oxide (FeNO).

Methods: A multicentre prospective observational trial, including 79 pwCF ≥ 18 years eligible for ETI.

View Article and Find Full Text PDF

Square and 4-7-8 breathing are popularly promoted by psychotherapists but have little empirical support. We hypothesized that breathing at 6 breaths per minute (bpm) would improve HRV, reduce blood pressure, and improve mood more than either square or 4-7-8 breathing. We also hypothesized square and 4-7-8 breathing would increase end-tidal CO (PETCO).

View Article and Find Full Text PDF

Tobacco use and exposure to tobacco products remain a major public health challenge, even among athletes. This study aimed to evaluate tobacco use and second-hand smoke exposure in athletes through urinary cotinine levels and exhaled air carbon monoxide (CO) measurements. This cross-sectional study included licensed athletes who visited the sports medicine outpatient clinic of a tertiary hospital.

View Article and Find Full Text PDF

Study on exhaled volatile organic compounds identifying cognitive fatigue induced by N-back task in healthy young adults.

Ecotoxicol Environ Saf

January 2025

National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China; China CDC Key Laboratory of Environment and Population Health, Beijing 100021, China. Electronic address:

Cognitive fatigue in specific occupations may present a risk to personal safety. The study aimed to explore the characteristic volatile organic compounds (VOCs) in exhaled breath in response to cognitive fatigue, to provide a scientific basis for the non-invasive exhaled breath diagnostic techniques for cognitive fatigue assessing. Thirty healthy young adults were recruited and assigned to complete two 1.

View Article and Find Full Text PDF

To reduce the risk of syncope, trained breath-hold divers (BHDs) use a specialized breathing technique after surfacing called "hook breathing" (HB). It consists of a full inspiration followed by a Valsalva-like maneuver and with subsequent exhalation performed against resistance to generate continuous positive airway pressure during exhalation. This study analyzed the influence of HB on oxygen saturation recovery after a -40 m depth apnea dive in trained BHDs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!