A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Coupled Dynamics of Droplet Impact on a Flexible, Hydrophilic Cantilever Beam. | LitMetric

We experimentally study the droplet impact on a flexible, hydrophilic cantilever beam. Droplets of water, water-glycerol (1:1 v/v), and glycerol were considered on a copper beam. Side visualization of the droplet impact on the cantilever was carried out by using a high-speed camera. We systematically vary cantilever stiffness to obtain a characteristic time scale of the beam dynamics, that is, shorter on the same order and longer than the characteristic time scale of droplet dynamics. Water droplet spreading reduces with an increase in the beam's flexibility, due to the "springboard effect". Results reveal that a threshold cantilever length exists beyond which the droplet vibration mode "locks-in" to the cantilever vibration mode. During lock-in, the bending energy of the beam increases with an increasing length or decreasing stiffness. The time-varying cantilever deflection exhibits an oscillatory, exponentially decaying response. However, in the case where both time scales are almost the same, we found a two-stage damping in the measurements: a fast, initial damping followed by a slower, damped response. We explain this damped response by the interplay of droplet and cantilever early dynamics. As expected, increasing the droplet viscosity dampens the magnitude of droplet spreading and displacement of the cantilever's tip due to a larger dissipation of kinetic energy in the bulk of the droplet. The decay is exponential in all cases, and the time taken to reduce the spreading and displacement is shorter with a larger viscosity. The damping coefficient is found to inversely scale with the cantilever length or mass. We corroborated the measurements with available analytical models, confirming the hypotheses used to explain the results. Overall, the present study provides fundamental insights into controlling the coupled dynamics of droplet and flexible substrates, with potential applications such as the design of efficient agricultural sprays and wings of microaerial vehicles.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.langmuir.3c02238DOI Listing

Publication Analysis

Top Keywords

droplet impact
12
droplet
11
cantilever
9
coupled dynamics
8
dynamics droplet
8
impact flexible
8
flexible hydrophilic
8
hydrophilic cantilever
8
cantilever beam
8
characteristic time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!