AI Article Synopsis

  • * The new method enhances mirror production by addressing issues like corrosion and thermal deformation, providing better stability and performance for high-quality x-ray optics.
  • * A vacuum degassing technique was developed to reduce bubble pit formation during fabrication, resulting in the successful creation of three pit-free mirrors for the FOXSI-4 project, with precise accuracy and performance comparable to leading x-ray missions.

Article Abstract

This study presents an approach for fabricating Wolter type-I mirrors for x-ray telescopes using a nickel electroforming replication process with quartz glass mandrels. The proposed method addresses the challenges encountered in conventional fabrication techniques, which involve using electroless nickel-coated aluminum mandrels that are susceptible to corrosion and thermal deformation. Quartz glass mandrels offer excellent chemical, thermal, and mechanical stability, enabling the efficient production of high-performance mirrors. Wolter type-I mirrors for telescopes possess a large aperture that collects x-ray photons from the universe. However, previous nickel electroforming replication processes using quartz glass mandrels have challenges in fabricating large mirrors, particularly due to bubble pit formation during nickel shell development. In this study, we introduced an efficient pitting inhibition technique via vacuum degassing. This technique facilitates the precise replication of pit-free Wolter type-I mirrors for telescopes using quartz glass mandrels. We demonstrated the fabrication process on a Wolter type-I mirror proposed for FOXSI-4 [(FOXSI) Focusing Optics X-ray Solar Imager], resulting in three mirrors obtained from the same mandrel without repolishing or repairing. The figure error of the mirror was within 1 µm over most areas in both longitudinal and circumferential directions. The ray-tracing simulation indicated that the performance of the mirror was ∼12 arcsec in half-power diameter, comparable to the performance achieved by previous high-resolution x-ray missions.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0160262DOI Listing

Publication Analysis

Top Keywords

wolter type-i
20
quartz glass
20
glass mandrels
20
nickel electroforming
12
electroforming replication
12
type-i mirrors
12
mirrors telescopes
8
mirrors
7
mandrels
6
wolter
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?