Extra robotic arms (XRAs) are gaining interest in neuroscience and robotics, offering potential tools for daily activities. However, this compelling opportunity poses new challenges for sensorimotor control strategies and human-machine interfaces (HMIs). A key unsolved challenge is allowing users to proficiently control XRAs without hindering their existing functions. To address this, we propose a pipeline to identify suitable HMIs given a defined task to accomplish with the XRA. Following such a scheme, we assessed a multimodal motor HMI based on gaze detection and diaphragmatic respiration in a purposely designed modular neurorobotic platform integrating virtual reality and a bilateral upper limb exoskeleton. Our results show that the proposed HMI does not interfere with speaking or visual exploration and that it can be used to control an extra virtual arm independently from the biological ones or in coordination with them. Participants showed significant improvements in performance with daily training and retention of learning, with no further improvements when artificial haptic feedback was provided. As a final proof of concept, naïve and experienced participants used a simplified version of the HMI to control a wearable XRA. Our analysis indicates how the presented HMI can be effectively used to control XRAs. The observation that experienced users achieved a success rate 22.2% higher than that of naïve users, combined with the result that naïve users showed average success rates of 74% when they first engaged with the system, endorses the viability of both the virtual reality-based testing and training and the proposed pipeline.

Download full-text PDF

Source
http://dx.doi.org/10.1126/scirobotics.adh1438DOI Listing

Publication Analysis

Top Keywords

extra robotic
8
control xras
8
naïve users
8
control
5
human motor
4
motor augmentation
4
augmentation extra
4
robotic arm
4
arm functional
4
functional interference
4

Similar Publications

Background: Robotic-assisted total joint arthroplasty (TJA) has gained popularity in recent years. Despite mixed patient and surgeon perceptions, conflicting evidence regarding efficacy and cost-effectiveness in comparison to manual TJA exists. Patients' beliefs surrounding robotic-assisted TJA remain unclear.

View Article and Find Full Text PDF

Unlabelled: Bladder paragangliomas are rare extra-adrenal urological tumors that account for around 0.05% of bladder cancers. Their diagnosis is often delayed because of the rarity of these tumors.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the prognostic significance of magnetic resonance imaging (MRI) parameters on biochemical failure-free survival (BFS) in patients diagnosed with intermediate-risk prostate cancer and treated with robotic ultrahypofractionated stereotactic body radiotherapy (SBRT) without androgen deprivation therapy (ADT).

Methods: A retrospective analysis was conducted in patients with intermediate-risk prostate cancer undergoing robotic SBRT delivered in five fractions with a total radiation dose of 35-36.25 Gy.

View Article and Find Full Text PDF

Functional alignment is a feasible alignment strategy in robotic assisted total knee arthroplasty for knee osteoarthritis with extra-articular deformity - A case series.

SICOT J

January 2025

Department of Orthopaedic Surgery, Joint Replacement Unit, Kuala Lumpur Hospital, Ministry of Health Malaysia, Jalan Pahang, 50586 Kuala Lumpur, Malaysia.

Introduction: Extraarticular deformity (EAD) with knee arthritis is a complex condition involving tri-planar bone deformity with pathological malalignment and chronic soft tissue contracture or laxity in the knee joint. Intraarticular correction by TKA, which was previously performed with conventional manual jig by mechanical alignment technique, had its limits and difficulties especially extensive soft tissue release and risk of jeopardizing the collateral ligaments. Robotic technology allows for reproducible and precise execution of surgical plan and allows adjustment to various new personalised alignment philosophy including functional alignment (FA).

View Article and Find Full Text PDF

Soft, Modular Power for Composing Robots with Embodied Energy.

Adv Mater

January 2025

Department of Mechanical and Aerospace Engineering, Cornell University, 124 Hoy Road, Ithaca, NY, 14850, USA.

The adaptable, modular structure of muscles, combined with their confluent energy storage allows for numerous architectures found in nature: trunks, tongues, and tentacles to name some more complex ones. To provide an artificial analog to this biological soft muscle, a self-powered, soft hydrostat actuator is presented. As an example of how to use these modules, a worm robot is assembled where the near totality of the body stores electrochemical potential.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!