Background: Preoperative percutaneous computed tomography (CT)-guided localization of pulmonary nodules plays a pivotal role in the diagnosis and treatment of early-stage lung cancer. However, conventional manual localization techniques have inherent limitations in achieving a high degree of accuracy. Consequently, a novel robotic-assisted navigation system was developed to attain precise localization of small lung nodules. This study aims to investigate the accuracy and safety of this system in clinical applications.
Methods: Patients with peripheral solitary pulmonary nodules measuring less than 20 mm were enrolled. The robotic-assisted navigation system generated a three-dimensional (3D) model based on the patient's CT images, determining the optimal puncture path. The robotic arm then accurately located the nodule and, following percutaneous puncture, indocyanine green (ICG) was injected. The primary outcome measure was the accuracy of pulmonary nodule localization, while secondary outcomes included the complication rate, procedural duration, and total radiation exposure.
Results: A total of 33 nodules were successfully localized using the robotic-assisted navigation system and resected through video-assisted thoracoscopic surgery (VATS). The first-pass success rate was 100%, with a median deviation of 6.1 mm [interquartile range (IQR), 2.5-7.2 mm] between the localizer and the nodule. The median localization time was 25.0 minutes, and the single and cumulative exam dose-length products (DLP) were 534.0 and 1491.0 mGy·cm, respectively. Notably, no observable complications were reported during the procedures.
Conclusions: The innovative robotic-assisted navigation system demonstrated satisfactory accuracy and holds promise for improving the percutaneous localization of lung nodules. This method represents a safe and viable alternative to traditional CT-guided manual localization techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10713270 | PMC |
http://dx.doi.org/10.21037/tlcr-23-493 | DOI Listing |
Ann Transl Med
December 2024
Department of Neurosurgery, Providence Neuroscience Center Everett, Everett, WA, USA.
Background: Robotic assistance has become increasingly prevalent in spinal surgery in recent years, emerging as a tool to increase accuracy and precision and lower complication rates and radiation exposure. The 7 and 8 Annual Seattle Science Foundation (SSF) Robotics Courses showcased presentations and demonstrations from some of the field's most experiences leaders on latest topics in robotics and spinal surgery, including cutting-edge preoperative planning technologies, augmented reality (AR) in the operating room, cervical fusion with transpedicular screws, and neuro-oncologic management. We provide a scoping review of the use of robotics technology in spinal surgery featuring highlights from the 7 and 8 Annual SSF Robotics Courses.
View Article and Find Full Text PDFJ Spine Surg
December 2024
Department of Orthopaedic Surgery, Changi General Hospital, Singapore, Singapore.
Background: Robotic-assisted spinal surgery has reportedly improved the accuracy of instrumentation with smaller incisions, improving surgical outcomes and reducing hospital stay. However, robot-assisted spine surgery has thus far been confined to placement of pedicle screw instrumentation only. This pilot study aims to explore the feasibility of utilizing the Mazor™ X Stealth Edition (Medtronic, Sofamor Danek USA), robotic-arm platform in the minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) procedure inclusive of interbody cage placement, in our institution.
View Article and Find Full Text PDFLangenbecks Arch Surg
January 2025
Department of Chemical Science & Engineering, School of Materials and Chemical Technology, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8552, Japan.
Purpose: We aimed to develop a novel fluorescent surgical gauze dyed with indocyanine green (ICG) to guide surgeons to the target anatomical destination during surgery for real-time navigation and to prevent gauze remnants after surgery.
Methods: Surgical gauze was dyed with an aqueous solution of ICG (5.0 × 10 mol L for Steraze, 1.
J Orthop
July 2025
Orthopedic Spine Surgeon, USA.
Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.
Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.
Life (Basel)
November 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico-Unità di Traumatologia dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza, 25124 Brescia, Italy.
Knee arthroplasty, commonly performed to treat osteoarthritis, necessitates precise surgical techniques for optimal outcomes. The introduction of systems such as the Persona Knee System (Zimmer Biomet, Warsaw, IN, USA) has revolutionized knee arthroplasty, promising enhanced precision and better patient outcomes. This study investigates the application of robotic planning specifically in knee prosthetic surgeries, with a focus on Persona Knee System prostheses.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!