A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative Radiation Exposure from O-arm-based 3D Navigation in Spine Surgery. | LitMetric

AI Article Synopsis

  • Intraoperative 3D imaging technology, specifically the O-arm surgical imaging system, provides real-time images during spinal surgeries and this study evaluates its radiation exposure.
  • The study analyzed data from 1599 spinal surgery patients and found that O-arm imaging was used in 206 cases, with patients receiving an average of 1.17 scans, varying by spinal region.
  • Results indicated that radiation exposure from O-arm imaging is generally lower than the established safety levels in Japan, but surgeons should still be cautious in high-fixation surgeries due to increased radiation risks.

Article Abstract

Introduction: Intraoperative three-dimensional (3D) imaging guide technology, such as the O-arm surgical imaging system, is a beneficial tool in spinal surgery that provides real-time 3D images of a patient's spine. This study aims to determine the exposure dose from intraoperative O-arm imaging.

Methods: A consecutive retrospective review of all patients undergoing spinal surgery was conducted between June 2019 and August 2022. Demographic and operative data were collected from electronic medical records.

Results: Intraoperative O-arm imaging was conducted in 206 (12.9%) of 1599 patients, ranging from one to 4 scans per patient (1.17±0.43 scans). Single O-arm imaging enabled navigation of seven vertebrae in the cervical spine, seven in the thoracic spine, five in the thoracolumbar spine, and four in the lumbar spine on average. The number of O-arm shots per surgery was 1.15±0.36, 1.06±0.24, 1.61±0.7, and 1.07±0.25 for cervical, thoracic, thoracolumbar, and lumbar spinal cases, respectively. The exposure doses represented by dose length products in single O-arm imaging were 377±19 mGy-cm, 243±22 mGy-cm, 378±38 mGy-cm, and 258±11 mGy-cm for cervical, thoracic, thoracolumbar, and lumbar spine cases, respectively. We observed a weak positive correlation between the number of fused spinal levels and the exposure dose.

Conclusions: Intraoperative radiation exposure from O-arm imaging was lower than the national diagnostic reference levels in Japan established based on the International Commission on Radiological Protection publication, demonstrating its safety from the standpoint of radiological protection in most cases. In surgeries with a large range of fixations, such as corrective deformity surgery, the number of imaging sessions and the amount of intraoperative radiation exposure would increase, leading surgeons to pay attention to the risk of radiation in spinal surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10710891PMC
http://dx.doi.org/10.22603/ssrr.2023-0057DOI Listing

Publication Analysis

Top Keywords

o-arm imaging
16
intraoperative radiation
12
radiation exposure
12
spinal surgery
12
intraoperative o-arm
8
single o-arm
8
lumbar spine
8
cervical thoracic
8
thoracic thoracolumbar
8
thoracolumbar lumbar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!