Objective: Silicone oils have the role in maintaining the attachment of the retina in conditions where the risk of retinal re-detachment is high. However, silicone oils have the tendency to emulsify with subsequent complications. In this work, analyses have been performed to understand changes that occurred to the optical, and physical characteristics of the oil after removal from the vitreous cavity of patients underwent pars plana vitrectomy (PPV) for fibrovascular membranes/tractional retinal detachment (FVM/TRD).
Methods: Four samples of silicone oil were allocated from patients who underwent PPV for FVM/TRD. The Fourier-transform infrared (FTIR) spectroscopy, micro-viscometry, and ultraviolet-visible spectrometer analyses were utilized to determine the changes in its chemical bondings, viscosity, absorbance, transmittance, buoyance, and specific gravity.
Results: The mean age of the patients was 49.0 years. The mean duration of silicone oil implantation was 18.9 months. FTIR analysis showed significant breaking in the chemical bonding that was related to the lens status during the primary PPV, the presence of significant retinal hemorrhages, the duration of silicone oil implantation, and the degree of silicone oil filling. Similarly, viscosity and contact angle analyses revealed a reduction in the viscosity with similar factors to the FTIR analysis. Moreover, absorbance and transmittance were largely affected by the aggressiveness of FVM/TRD.
Conclusion: This study revealed that certain factors such as the age of the patient, duration of silicone oil implantation, lens status, and the presence of retinal hemorrhages, the degree of silicone oil filling and aggressiveness of FVM/TRD may contribute to the emulsification process.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10710780 | PMC |
http://dx.doi.org/10.2147/OPTH.S447099 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!