A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Direct Determination of Ca, K, and Mg in Soy Leaf Samples Using Laser-Induced Breakdown Spectroscopy. | LitMetric

This study was dedicated to developing analytical methods for determining macronutrients (Ca, K, and Mg) in soy leaf samples with and without petioles. The study's primary purpose was to present Laser-induced breakdown spectroscopy (LIBS) as a viable alternative for directly analyzing leaf samples using chemometric tools to interpret the data obtained. The instrumental condition chosen for LIBS was 70 mJ of laser pulse energy, 1.0 µs of delay time, and 100 µm of spot size, which was applied to 896 samples: 305 of soy without petioles and 591 of soy with petioles. The reference values of the analytes for the proposition of calibration models were obtained using inductively coupled plasma optical emission spectroscopy (ICP-OES) technique. Twelve normalization modes and two calibration strategies were tested to minimize signal variations and sample matrix microheterogeneity. The following were studied: multivariate calibration using partial least squares and univariate calibration using the area and height of several selected emission lines. The notable normalization mode for most models was the Euclidean norm. No analyte showed promising results for univariate calibrations. Micronutrients, P and S, were also tested, and no multivariate models presented satisfactory results. The models obtained for Ca, K, and Mg showed good results. The standard error of calibration ranged from 2.3 g/kg for Ca in soy leaves without petioles with two latent variables to 5.0 g/kg for K in soy leaves with petioles with two latent variables.

Download full-text PDF

Source
http://dx.doi.org/10.1177/00037028231217974DOI Listing

Publication Analysis

Top Keywords

leaf samples
12
soy leaf
8
laser-induced breakdown
8
breakdown spectroscopy
8
soy petioles
8
soy leaves
8
leaves petioles
8
petioles latent
8
latent variables
8
soy
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!