The field of robotic microsurgery and micro-manipulation has undergone a profound evolution in recent years, particularly with regard to the accuracy, precision, versatility, and dexterity. These advancements have the potential to revolutionize high-precision biomedical procedures, such as neurosurgery, vitreoretinal surgery, and cell micro-manipulation. However, a critical challenge in developing micron-precision robotic systems is accurately verifying the end-effector motion in 3D. Such verification is complicated due to environmental vibrations, inaccuracy of mechanical assembly, and other physical uncertainties. To overcome these challenges, this paper proposes a novel single-camera framework that utilizes mirrors with known geometric parameters to estimate the 3D position of the microsurgical instrument. Euclidean distance between reconstructed points by the algorithm and the robot movement recorded by the highly accurate encoders is considered an error. Our method exhibits an accurate estimation with the mean absolute error of 0.044 mm when tested on a 23G surgical cannula with a diameter of 0.640 mm and operates at a resolution of 4024 × 3036 at 30 frames per second.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC40787.2023.10340955 | DOI Listing |
Annu Int Conf IEEE Eng Med Biol Soc
July 2023
The field of robotic microsurgery and micro-manipulation has undergone a profound evolution in recent years, particularly with regard to the accuracy, precision, versatility, and dexterity. These advancements have the potential to revolutionize high-precision biomedical procedures, such as neurosurgery, vitreoretinal surgery, and cell micro-manipulation. However, a critical challenge in developing micron-precision robotic systems is accurately verifying the end-effector motion in 3D.
View Article and Find Full Text PDFBiosensors (Basel)
March 2021
Institut Jean Lamour, Lorraine University (CNRS-UMR 7198), F54000 Nancy, France.
The measurement of glycemia is impacted by several constraints; those constraints have to be identified and quantified when designing an electromagnetic noninvasive sensor. The second phase concerns the level of the influence of these constraints. In this work, we investigated the impact of vein radius located in the forearm on a resonant microwave sensor to measure glycemia.
View Article and Find Full Text PDFChirality
August 2020
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Comenius University, Bratislava, Slovakia.
Citalopram (CIT) is a frequently used modern antidepressant that inhibits selectively serotonin reuptake in the brain. It has a chiral center in its structure and is used in therapy as both racemic mixture and pure enantiomer as its pharmacological effect is almost entirely associated with S-CIT. The aim of this study was the development of a simple and rapid capillary electrophoresis (CE) method for the separation and quantification of CIT enantiomers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!