  • Patients with previous heart attacks (MIs) face higher risks of future events, especially when stressed, prompting the need for effective monitoring tools.
  • A new miniaturized patch designed to record multiple heart signals (ECG, SCG, PPG) has shown promising results in matching key ECG-derived features with those from a standard device (Biopac) during stress tests, indicating its potential reliability.
  • The strong correlation in data (e.g., heart rate and variability) suggests that this patch could be clinically beneficial for monitoring post-MI patients and enhancing their outcomes, pending further evaluation.

Article Abstract

Patients with prior myocardial infarction (MI) have an increased risk of experiencing a secondary event which is exacerbated by mental stress. Our team has developed a miniaturized patch with the capability to capture electrocardiogram (ECG), seismocardiogram (SCG) and photoplethysmogram (PPG) signals which may provide multimodal information to characterize stress responses within the post-MI population in ambulatory settings. As ECG-derived features have been shown to be informative in assessing the risk of MI, a critical first step is to ensure that the patch ECG features agree with gold-standard devices, such as the Biopac. However, this is yet to be done in this population. We, thus, performed a comparative analysis between ECG-derived features (heart rate (HR) and heart rate variability (HRV)) of the patch and Biopac in the context of stress. Our dataset contained post-MI and healthy control subjects who participated in a public speaking challenge. Regression analyses for patch and Biopac HR and HRV features (RMSSD, pNN50, SD1/SD2, and LF/HF) were all significant (p<0.001) and had strong positive correlations (r>0.9). Additionally, Bland-Altman analyses for most features showed tight limits of agreement: 0.999 bpm (HR), 11.341 ms (RMSSD), 0.07% (pNN50), 0.146 ratio difference (SD1/SD2), 0.750 ratio difference (LF/HF).Clinical relevance- This work demonstrates that ECG-derived features obtained from the patch and Biopac are in agreement, suggesting the clinical utility of the patch in deriving quantitative metrics of physiology during stress in post-MI patients. This has the potential to improve post-MI patients' outcomes, but needs to be further evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC40787.2023.10340614DOI Listing

Publication Analysis

Top Keywords

ecg-derived features
12
patch biopac
12
myocardial infarction
8
heart rate
8
ratio difference
8
patch
7
features
7
quantifying stress
4
stress patients
4
patients history
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!