A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Does Charge Balancing Ensure the Safety of the Electrical Stimulation and Is It Power Efficientƒ. | LitMetric

Safety issues are the most important concern in electrical stimulation. Equating the charge in the anodic and cathodic phases, namely charge balancing or charge equalizing, is a well-known method to avoid tissue damage and/or electrode corrosion. The electrode-tissue interface is not ideal in practice and with a charge-balanced waveform, the electrode voltage becomes more positive compared to the pre-pulse value and corrosion happens. In this paper, we show that a charge balancer ensures the safety of stimulation if the rate of the irreversible Faradaic reactions is negligible, or when the pulse width of the stimulation phases is not comparable to the time constant of the electrode-tissue interface. Furthermore, charge balancing is studied with mathematical modeling for different types of tissue models, and the results are used to show the conditions that charge balancing does not ensure the safety of the electrical stimulation, and employing charge balancing not only increases the power consumption of the electrical-stimulation systems but also increases the rate of the electrode corrosion in these conditions. The main goal of this paper is to show that a charge controller is a general solution for ensuring the safety of the electrical stimulation, with an efficient, not excessive, amount of charge for the reversal phase and should be employed instead of charge balancers in generic stimulators.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC40787.2023.10340438DOI Listing

Publication Analysis

Top Keywords

charge balancing
20
electrical stimulation
16
safety electrical
12
charge
11
balancing ensure
8
ensure safety
8
electrode corrosion
8
electrode-tissue interface
8
paper charge
8
stimulation
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!