Tissue responses can cause a significant reduction in the performance of microelectrode-based devices implanted into neural tissue. Since the reduction of the thickness of implants has been shown to reduce tissue response, in this work we report on our effects to reduce the thickness of our tissue-engineered-electronic-nerve-interface (TEENI) devices and characterize their long-term reliability in a harsh environment. We were able to reduce the thickness of the TEENI threads that are to be located in nerve tissue from ~10 μm to ~2.5 μm in total thickness. To maintain the handleability needed during the assembly of the TEENI device into the hydrogel-based scaffold, we maintained full thickness elsewhere in the TEENI device and added support rails. During longitudinal reactive-accelerated-aging (RAA) experiments performed over 6 days and at 67°C, which corresponds to ~48 days in tissue, we observed that some channels maintain a stable impedance and others do not. Although analyses performed using a scanning electron microscope could clearly reveal delamination in some channels that exhibited large changes in impedance, it did not always correlate. Some channels with significant changes in impedance did not exhibit any observable delamination. Additional work is needed to study the relationship between changes in impedance and structural changes in the device, with the goal of improving device design to achieve longer-lasting devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC40787.2023.10340337 | DOI Listing |
Medicine (Baltimore)
January 2025
Department of Clinical Nutrition, Tongde Hospital of Zhejiang Province, Hangzhou, China.
There are limited studies on the phase angle (PhA) and sarcopenic obesity (SO) in the Chinese population. This study aimed to establish 50 kHz-PhA reference data for SO population, and to evaluate the correlation between 50 kHz-PhA and SO. A total of 10,312 participants including 5415 men and 4897 women were enrolled in this study, and their resistance and reactance at 50 kHz, and body composition parameters were measured a segmental multifrequency bioelectrical impedance analysis device (InBody 720).
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
January 2025
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Increased blood pressure upon standing is considered a cardiovascular risk factor. We investigated the reproducibility of changes in aortic blood pressure, heart rate, stroke volume, cardiac output, and systemic vascular resistance during three passive head-up tilts (HUT) in 223 participants without cardiovascular medications (mean age 46 years, BMI 28 kg/m2, 54% male). Median time gap between the first and the second HUT was 9 weeks and the second and the third HUT 4 weeks.
View Article and Find Full Text PDFActa Otolaryngol
January 2025
Department of Audiology and Prevention of Communication Disorders, All India Institute of Speech and Hearing, Mysuru, Karnataka, India.
Background: Although Cochlear implantation (CI) is effective in restoring hearing for children with severe-to-profound sensorineural hearing loss, it may influence the middle ear mechanics, potentially causing an air-bone gap and altering middle ear stiffness, which is not detected by traditional 226 Hz tympanometry.
Aims/objectives: To investigate the effect of mastoidectomy posterior tympanotomy (MPTA) on wideband absorbance (WBA) in children with CI.
Materials And Methods: The study included 20 normal-hearing children (normal group) and 10 children with CIs who underwent MPTA (CI-MPTA group), aged 3-10 years.
Biomed Microdevices
January 2025
Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, 08854, USA.
Wearable and implantable biosensors have rapidly entered the fields of health and biomedicine to diagnose diseases and physiological monitoring. The use of wired medical devices causes surgical complications, which can occur when wires break, become infected, generate electrical noise, and are incompatible with implantable applications. In contrast, wireless power transfer is ideal for biosensing applications since it does not necessitate direct connections between measurement tools and sensing systems, enabling remote use of the biosensors.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Department of Biomedical Engineering, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea. Electronic address:
Glycosylation, the intricate process of adding carbohydrate motifs to proteins, lipids, and exosomes on the cell surface, is crucial for both physiological and pathological mechanisms. Alterations in glycans significantly affect cancer cell metastasis by mediating cell-cell and cell-matrix interactions. The subtle changes in glycosylation during malignant transformations highlight the importance of analyzing cell and exosome surface glycosylation for prognostic and early treatment strategies in cancer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!