Several portable commercial bioimpedance spectroscopy (BIS) devices are used in clinical research, but are limited by their reduced impedance measuring range to less demanding four-electrode configuration measurements. Some of these devices provide raw bioimpedance data for research purposes. The SFB7 device from ImpediMed® is a typical portable clinical device which perform 256 measurement points from 3 kHz to 1 MHz, providing for each point the resistance R and the reactance X. Its main drawback is its impedance range, limited to only 1100 Ω, making it less suitable for more demanding, higher impedance, two-electrode measurements which are potentially of great clinical interest. Some benchtop reference devices have larger frequency and impedance ranges than the SFB7 but are not portable and are not designed specifically for BIS measurement on humans.This article proposes a method to overcome the impedance range limitation of the SFB7 by connecting in parallel to the investigated bioimpedance a fixed and known impedance, whose value (and hence that of the total measured impedance) is within the device's range. The investigated impedance is then calculated by eliminating the contribution of the known impedance via a post processing of the data.This concept has been successfully tested on a physical model, and an in vivo example has validated the practicality of performing demanding two-electrode measurements on individuals using a SFB7, with relative errors of R and X inferior to 2.5% and 7% respectively.Clinical Relevance- Using the proposed setup and after post processing of the data, the SFB7 BIS device can now be used to perform demanding two-electrode measurements, hitherto impossible, enabling a range of novel clinical, high-impedance studies, for example for localized skin characterization.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC40787.2023.10340265DOI Listing

Publication Analysis

Top Keywords

impedance range
12
two-electrode measurements
12
impedance
10
device perform
8
post processing
8
demanding two-electrode
8
range
6
clinical
5
sfb7
5
overcoming impedance
4

Similar Publications

The aim was to estimate the prevalence of low muscle mass (LMM) and low muscle mass associated with obesity (LMM-O) in healthy adult, and to verify the performance of raw bioelectrical impedance parameters (BIA) and vector analysis (BIVA) in the screening of this tow conditions. This is a cross-sectional study including 1025 healthy adults. Body composition was assessed by the BIA technique.

View Article and Find Full Text PDF

To measure the electroacoustic parameters of transducers in the continuous sound field in a limited water area, a reciprocity calibration method of hydrophones using a spatial sampling average method in a non-anechoic tank was developed. The sound propagation in the non-anechoic tank under the impedance boundary condition, with a sound source producing continuous sound, is introduced based on the Helmholtz equation and Green's function. The reciprocity constant is given using the spatial sampling average sound pressure, and the three-transducer reciprocity calibration procedure was established.

View Article and Find Full Text PDF

In recent years, the increasing prevalence of viral infections such as dengue (DENV) and chikungunya (CHIKV) has emphasized the vital need for new diagnostic techniques that are not only quick and inexpensive but also suitable for point-of-care and home usage. Existing diagnostic procedures, while useful, sometimes have limits in terms of speed, mobility, and price, particularly in resource-constrained environments and during epidemics. To address these issues, this study proposes a novel technique that combines 3D printing technology with electrochemical biosensors to provide a highly sensitive, user-friendly, and customizable diagnostic platform.

View Article and Find Full Text PDF

Chemotherapy is a crucial cancer treatment, but its effectiveness requires precise monitoring of drug concentrations in patients. This study introduces an innovative electrochemical strip sensor design to detect and continuously monitor methotrexate (MTX), a key chemotherapeutic drug. The sensor is crafted through an eco-friendly synthesis process that produces porous reduced graphene oxide (PrGO), which is then integrated with gold nanocomposites and polypyrrole (PPy) to boost the performance of a screen-printed carbon electrode (SPCE).

View Article and Find Full Text PDF

Impact of diagnostic testing on outcomes of children with rumination syndrome.

J Pediatr Gastroenterol Nutr

January 2025

Department of Pediatrics, Division of Gastroenterology, Hepatology, and Nutrition, Nationwide Children's Hospital, Columbus, Ohio, USA.

Objectives: Rumination syndrome (RS) is diagnosed based on clinical criteria with or without diagnostic testing showing characteristic findings on antroduodenal manometry (ADM), high-resolution esophageal manometry (HREM), and multichannel intraluminal impedance-pH testing (MII-pH). The objective of this study was to evaluate the correlation between diagnostic testing and clinical outcomes.

Methods: We conducted a retrospective review of children with RS evaluated at our institution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!