Electrical impedance tomography (EIT) has been employed in the field of medical imaging due to its cost effectiveness, safety profile and portability, but the images generated are relatively low resolution. To address these limitations, we create a novel method using EIT images to generate high resolution structurally aligned images of lungs like those from CT scans. A way to achieve this transformation is via Cycle generative adversarial networks (CycleGAN), which have demonstrated image-to-image translation capabilities across different modalities. However, a generic implementation yields images which may not be aligned with their input image. To solve this issue, we construct and incorporate a Mutual Information (MI) constraint in CycleGAN to translate functional lung EIT images to structural high resolution CT images. The CycleGAN is first trained on unpaired EIT and CT lung images. Afterwards, we generate CT image pairs from EIT images via CycleGANs constrained with MI loss and without this loss. Finally, through generating these 1560 CT image pairs and then comparing the visual results and quantitative metrics, we show that MI constrained CycleGAN produces more structurally aligned CT images, where Normalised Mutual Information (NMI) is increased to 0.2621+/- 0.0052 versus 0.2600 +/- 0.0066, p<0.0001 for non-MI constrained images. By this process, we simultaneously provide functional and structural information, and potentially enable more detailed assessment of lungs.Clinical Relevance- By establishing a structurally aligning generative process via MI Loss in CycleGAN, this study enables EIT-CT conversion, thereby providing functional and structural images for enhanced lung assessment, from just EIT images.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC40787.2023.10340711DOI Listing

Publication Analysis

Top Keywords

eit images
16
structurally aligned
12
aligned images
12
images
11
images generate
8
high resolution
8
image pairs
8
eit
6
cyclegan
5
cyclegan mutual
4

Similar Publications

Dynamic EIT technology for real-time non-invasive monitoring of acute pulmonary embolism: a porcine model experiment.

Respir Res

January 2025

Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi'an, 710032, China.

Background: Acute pulmonary embolism represents the third most prevalent cardiovascular pathology, following coronary heart disease and hypertension. Its untreated mortality rate is as high as 20-30%, which represents a significant threat to patient survival. In view of the current lack of real-time monitoring techniques for acute pulmonary embolism, this study primarily investigates the potential of the pulsatility electrical impedance tomography (EIT) technique for the detection and real-time monitoring of acute pulmonary embolism through the collection and imaging of the pulsatile signal of pulmonary blood flow.

View Article and Find Full Text PDF

Background: Predicting complete liberation from mechanical ventilation (MV) is still challenging. Electrical impedance tomography (EIT) offers a non-invasive measure of regional ventilation distribution and could bring additional information.

Research Question: Whether the display of regional ventilation distribution during a Spontaneous Breathing Trial (SBT) could help at predicting early and successful liberation from MV.

View Article and Find Full Text PDF

Breast cancer is the most commonly diagnosed neoplasm and one of the most widespread cancers among women. The research advanced the Mf-EIT hardware through analogue discovery, component assessment, hardware integration, software creation, and data reconstruction utilizing Gauss-Newton and GREIT approaches. The breast cancer phantom consisted of a gelatin and sodium chloride solution.

View Article and Find Full Text PDF

Analyzing the TotalSegmentator for facial feature removal in head CT scans.

Radiography (Lond)

January 2025

Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany; Berlin Institute of Health, Berlin, Germany.

Background: Facial recognition technology in medical imaging, particularly with head scans, poses privacy risks due to identifiable facial features. This study evaluates the use of facial recognition software in identifying facial features from head CT scans and explores a defacing pipeline using TotalSegmentator to reduce re-identification risks while preserving data integrity for research.

Methods: 1404 high-quality renderings from the UCLH EIT Stroke dataset, both with and without defacing were analysed.

View Article and Find Full Text PDF

Aim: The aim of this study was to introduce the Esophagus-Sparing Anastomotic Narrowing Revision (ESANR) technique for the intraoperative management of anastomotic narrowing and to conduct a literature review to provide an algorithm for the management of narrowing and strictures that may develop secondary to esophagojejunostomy.

Methods: Three patients with anastomotic narrowing during esophagojejunostomy were analyzed between September 2019 and June 2024. The anastomotic narrowing was detected by intraoperative gastroscopy after reconstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!