Does needle size matter? Effects of micro-hypodermic needle injections of botulinum toxin type A in patients with hemifacial spasm.

Parkinsonism Relat Disord

Chulalongkorn Centre of Excellence for Parkinson's Disease and Related Disorders, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand; The Academy of Science, The Royal Society of Thailand, Bangkok, Thailand. Electronic address:

Published: January 2024

Introduction: Botulinum toxin type A (BoNT/A) injections are the first-line treatment for primary hemifacial spasms (HFS), but require frequent painful injections. Although micro-hypodermic needles are commonly used for aesthetic BoNT/A injections to lessen pain and bruising, their benefits in HFS remain unclear.

Objective: To compare side effects of BoNT/A injection, specifically pain and bruising, between primary HFS patients who received injections using micro-hypodermic needles (34-G) and those using standard needles (30-G).

Methods: This cross-over, double-blind, randomised controlled trial involved HFS patients who received BoNT/A injections using either a 34-G or 30-G needle at two visits 12 weeks apart. Primary outcomes, pain and bruising were assessed immediately after injection using the Visual Analogue Scale (VAS) and Short-form McGill Pain Questionnaire (Thai version, SF-MPQ). Bruise assessment was also conducted one week after each injection. Secondary outcomes involved comparing efficacy of BoNT/A between the two types of needles and assessing other complications beyond pain and bruising.

Results: 65 HFS patients (47 women and 18 men; mean age 59.46 ± 11.48 years; mean disease duration 5.86 ± 4.16 years) were included in the study. Patients who received 34-G needle injections reported significantly reduced pain, as indicated by VAS, total SF-MPQ scores, and bruise scores, compared to those who received 30-G needle injections (p < 0.001, each). There were no differences in efficacy or occurrence of other complications associated with BoNT/A between the two needle types.

Conclusion: In HFS patients, BoNT/A injections using micro-hypodermic needles resulted in reduced pain and bruising, compared to standard needles, while maintaining similar BoNT/A benefits.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.parkreldis.2023.105950DOI Listing

Publication Analysis

Top Keywords

needle injections
12
bont/a injections
12
pain bruising
12
hfs patients
12
patients received
12
injections
8
botulinum toxin
8
toxin type
8
injections micro-hypodermic
8
micro-hypodermic needles
8

Similar Publications

Electrospinning can be used to prepare membranes with characteristics for biomedical application. In this work, the electrospinning conditions for the fabrication of membranes based on polymers extracted from natural sources such as chitosan and collagen were optimized (injection flow, injection volume, distance from the collector to the neddle, needle size and voltage). Specifically, four formulations were prepared with pure chitosan and mixtures of collagen (purified or hydrolyzed) and agarose.

View Article and Find Full Text PDF

Purpose: To present a novel bended-needle drainage system in vitreous cavity lavage (VCL) for postoperative vitreous cavity hemorrhage (POVCH).

Methods: This retrospective case series include all patients with POVCH who received VCL with the bended-needle drainage system at ophthalmology department of Peking Union Medical College Hospital from January 2022 to May 2024. Patients adopted a supine position that allows preparation and draping.

View Article and Find Full Text PDF

Purpose: To develop a simple tool to remove retained submacular perfluorocarbon liquid bubbles (R-PFCL) and to inject recombinant tissue plasminogen activator safely in subretinal space in submacular hematomas.

Method: A retrospective, interventional study was performed where a simple homemade micro-viscous fluid control was developed to gain access to subretinal space in a controlled way. The rubber cap of the plunger of a 1-mL syringe was cut; this cut rubber cap of the plunger was fitted inside an empty 1-mL tuberculin syringe, and its end was fitted with the tubings of viscous fluid control of the vitrectomy machine.

View Article and Find Full Text PDF

Failed Spinal Anesthesia: Incidence and Associated Factors.

Cureus

December 2024

Department of Anaesthesiology, Dr. D. Y. Patil Medical College, Hospital & Research Centre, Dr. D. Y. Patil Vidyapeeth (Deemed to be University), Pune, IND.

Introduction Spinal anesthesia, a commonly used technique for lower abdominal, pelvic, and lower extremity surgeries, involves injecting a local anesthetic into the subarachnoid space to temporarily block sensory, motor, and sympathetic nerves. Despite its high success rate, the failure of spinal anesthesia, which can lead to adverse patient outcomes, remains a concern. The failure rate varies widely, from 1% to 17%, influenced by factors such as technical challenges, patient anatomy, and practitioner experience.

View Article and Find Full Text PDF

We present the case of a 12-year-old girl with vesicoureteral reflux (VUR) of a solitary kidney treated using a modified hydrodistention implantation technique. A needle was set parallel to the ureteral guidewire inserted through the ureteral orifice before performing injections to correct VUR. Multi-site tandem injections were administered along the wire, which confirmed the direction and length of the ureteral tunnel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!