AI Article Synopsis

  • Intracoronary imaging enhances clinical outcomes for complex coronary bifurcation lesions (CBLs), but the influence of Medina classification on these outcomes is not well understood.
  • This study analyzed data from four prior studies involving 763 CBLs treated with drug-eluting stents and imaging guidance, focusing on major adverse cardiac events (MACE) at a one-year follow-up.
  • The results showed that the 0-0-1 Medina subtype had significantly higher risks for MACE and target lesion revascularization compared to the 0-1-0 subtype, while similar outcomes were observed in true and non-true CBLs except for the 0-0-1 lesions.

Article Abstract

Background: Intracoronary imaging improves clinical outcomes after stenting of complex coronary bifurcation lesions (CBLs), but the impact of Medina classification-based CBL distribution on outcomes of imaging-guided bifurcation stenting is unclear.

Methods: In this integrated analysis of four previous studies, in which all CBLs were treated with drug-eluting stents under intravascular ultrasound or optical coherence tomography guidance, the distribution of 763 CBLs was assessed using angiographic Medina classification. Major adverse cardiac events (MACE), including target lesion revascularization (TLR), myocardial infarction, stent thrombosis, and cardiac death, were investigated at 1-year follow-up.

Results: The most and least prevalent Medina subtypes were 0-1-0 (27.9 %) and 0-0-1 lesions (2.8 %). The most and least frequent MACE/TLR rates were 18.2 %/18.2 % for 0-0-1 lesions and 4.1 %/2.8 % for 0-1-0 lesions. Risks were higher for 0-0-1 lesions than for 0-1-0 lesions for both MACE (hazard ratio [HR]: 4.04, 95 % confidence interval [CI]: 1.21-13.45, p = 0.02) and TLR (HR: 6.19, 95 % CI: 1.69-22.74, p = 0.006). MACE rates were similar for true and non-true CBLs excluding 0-0-1 lesions (8.2 % and 5.9 %, HR 1.54, 95 % CI: 0.86-2.77, p = 0.15), while MACE (HR: 3.25, 95 % CI: 1.10-9.63, p = 0.03) and TLR (HR: 4.24, 95 % CI: 1.38-12.96, p = 0.01) risks were higher for 0-0-1 lesions.

Conclusions: This integrated analysis of imaging-guided bifurcation stenting demonstrated similar clinical outcomes in true and non-true CBLs, except for 0-0-1 lesions, which had a significantly higher risk of MACE/TLR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10700802PMC
http://dx.doi.org/10.1016/j.ijcha.2023.101311DOI Listing

Publication Analysis

Top Keywords

0-0-1 lesions
20
clinical outcomes
12
bifurcation stenting
12
impact medina
8
medina classification
8
outcomes imaging-guided
8
coronary bifurcation
8
lesions
8
imaging-guided bifurcation
8
integrated analysis
8

Similar Publications

Objective: To evaluate the relationship between infarct pattern, inferred stroke mechanism and risk of recurrence in patients with ischaemic stroke. The question is clinically relevant to optimise secondary stroke prevention investigations and treatment.

Design: We conducted a retrospective analysis of the dabigatran treatment of acute stroke II (DATAS II) trial (ClinicalTrials.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares the definitions of high-volume disease (HVD) and low-volume disease (LVD) in metastatic hormone-sensitive prostate cancer (mHSPC) patients using both conventional imaging (CI) and prostate-specific membrane antigen (PSMA) PET imaging, highlighting the need for more accurate definitions for treatment decisions.
  • Researchers analyzed data from 67 mHSPC patients across five international sites who had both PSMA PET and CI scans within a specific timeframe, assessing how many were classified as HVD or LVD based on each imaging method.
  • Results showed a significant discrepancy in classification: 25.4% of patients were identified as HVD using CI, while 40.3% were identified as HVD using
View Article and Find Full Text PDF

Limited evidence exists regarding the long-term outcomes of true versus nontrue coronary bifurcation lesions (CBLs) treated with current-generation drug-eluting stents and intravascular imaging guidance. The Sapporo Cardiovascular Clinic (SCVC) registry was a prospective, single-center, all-comers registry enrolling 1,727 consecutive patients treated with bioresorbable polymer sirolimus-eluting stent under complete imaging guidance. From this registry, 440 patients with CBLs (25.

View Article and Find Full Text PDF

The Medina classification separates true bifurcation lesions into three unnecessary groups: 1.1.1, 1.

View Article and Find Full Text PDF

Decoding medina 0.0.1 bifurcation: Are all codes equal? Results from a multicentric registry.

Int J Cardiol

February 2025

Institut Cardiovasculaire Paris Sud, Ramsay Générale de Santé, Massy, France. Electronic address:

Objectives: This study aimed to detail the technical management of Medina 0.0.1 lesions, assess their outcomes, and identify predictors of Major Adverse Cardiovascular Events (MACE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!