Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Sacral laminoplasty with titanium mesh and titanium screws can reduce symptomatic sacral extradural spinal meningeal cysts (SESMCs) recurrence and operation complications. However, due to a defect or thinning of the sacrum, the screws cannot be securely anchored and there are also problems with permanent metal implantation for titanium mesh and screws. We propose that sacral laminoplasty with absorbable clamps can provide rigid fixation even for a thinned or defected sacrum without leaving permanent metal implants.
Methods: In the direct microsurgical treatment of symptomatic SESMCs, we performed one-stage sacral laminoplasty with autologous sacral lamina reimplantation fixed by absorbable fixation clamps. Retrospectively, we analyzed intraoperative handling, planarity of the sacral lamina, and stability of the fixation based on clinical and radiological data.
Results: Between November 2021 to October 2022, we performed sacral laminoplasty with the absorbable craniofix system in 28 consecutive patients with SESMCs. The size of the sacral lamina flaps ranged from 756 to 1,052 mm (average 906.21 ± 84.04 mm). We applied a minimum of two (in four cases) and up to four (in four cases) Craniofix clamps in the operation, with three (in 20 cases) being the most common (82.14%, 20/28) and convenient to handle. Excellent sacral canal reconstruction could be confirmed intraoperatively by the surgeons and postoperatively by CT scans. No intraoperative complications occurred.
Conclusions: One-stage sacral laminoplasty with absorbable fixation clamps is technically feasible, and applying 3 of these can achieve a stable fixation effect and are easy to operate. Restoring the normal structure of the sacral canal could reduce complications and improve surgical efficacy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10702746 | PMC |
http://dx.doi.org/10.3389/fsurg.2023.1253432 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!