Purpose: To systematically investigate the impact of image preprocessing parameters on the segmentation-based reproducibility of magnetic resonance imaging (MRI) radiomic features.

Methods: The MRI scans of 50 patients were included from the multi-institutional Brain Tumor Segmentation 2021 public glioma dataset. Whole tumor volumes were manually segmented by two independent readers, with the participation of eight readers. Radiomic features were extracted from two sequences: T2-weighted (T2) and contrast-enhanced T1-weighted (T1ce). Two methods were considered for discretization: bin count (i.e., relative discretization) and bin width (i.e., absolute discretization). Ten discretization (five for each method) and five resampling parameters were varied while other parameters were fixed. The intraclass correlation coefficient (ICC) was used for reliability analysis based on two commonly used cut-off values (0.75 and 0.90).

Results: Image preprocessing parameters had a significant impact on the segmentation-based reproducibility of radiomic features. The bin width method yielded more reproducible features than the bin count method. In discretization experiments using the bin width on both sequences, according to the ICC cut-off values of 0.75 and 0.90, the rate of reproducible features ranged from 70% to 84% and from 35% to 57%, respectively, with an increasing percentage trend as parameter values decreased (from 84 to 5 for T2; 100 to 6 for T1ce). In the resampling experiments, these ranged from 53% to 74% and from 10% to 20%, respectively, with an increasing percentage trend from lower to higher parameter values (physical voxel size; from 1 x 1 x 1 to 2 x 2 x 2 mm).

Conclusion: The segmentation-based reproducibility of radiomic features appears to be substantially influenced by discretization and resampling parameters. Our findings indicate that the bin width method should be used for discretization and lower bin width and higher resampling values should be used to allow more reproducible features.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11095065PMC
http://dx.doi.org/10.4274/dir.2023.232543DOI Listing

Publication Analysis

Top Keywords

bin width
20
segmentation-based reproducibility
16
radiomic features
16
image preprocessing
12
reproducibility radiomic
12
resampling parameters
12
reproducible features
12
discretization
8
discretization resampling
8
preprocessing parameters
8

Similar Publications

Unveiling the Centrosymmetric Effect in the Design of Narrowband Fluorescent Emitters: From Single to Double Difluoroboron Cores.

J Am Chem Soc

December 2024

Key Laboratory of Green Chemistry and Technology of Ministry of Education, College of Chemistry, Sichuan University, 29 Wangjiang Road, Chengdu 610064, People's Republic of China.

Narrowband fluorescent emitters are receiving significant attention due to the great potential for creating ultrahigh-definition organic light-emitting diode displays (UHD-OLED). Unveiling innovative mechanisms to design new high-performance narrowband fluorescent emitters is a concerted endeavor in both academic and industrial circles. Theoretical calculations reveal that the centrosymmetric dianilido-bipyridine boron difluoride framework (-DAPBF) exhibits significantly reduced structural relaxation compared to previously reported asymmetric structures with monofluoroboron cores, creating new opportunities for the development of narrowband fluorescent emitters.

View Article and Find Full Text PDF

Achieving desired characteristic impedances in customized coplanar waveguide transmission line design.

MethodsX

December 2024

Department of Electrical Engineering, College of Engineering Al-Hussein Bin Talal, University, Ma'an 71111, Jordan.

Coplanar waveguide (CPW) transmission lines are valued for their planar design, low radiation, and minimized signal loss, but controlling their characteristic impedance remains a challenge. This study employs the Taguchi method, a statistical approach, to optimize the characteristic impedance by adjusting eight control factors: track width, track thickness, gap width, dielectric height, backplane thickness, conductor material conductivity, dielectric conductivity, and operational frequency. The analysis evaluates these factors across three levels to find optimal conditions, with dielectric height and track width identified as most influential.

View Article and Find Full Text PDF

Application of a 3D Fusion Model to Evaluate the Efficacy of Clear Aligner Therapy in Malocclusion Patients: A Prospective Observational Study.

J Med Internet Res

December 2024

Kunming Medical University Affiliated Stomatological Hospital & Yunnan Key Laboratory of Stomatology, Department of Orthodontics, Kunming Medical University, C Building, Hecheng International1088 Haiyuan Middle Road, Kunming, CN.

Background: Investigating the safe range of orthodontic tooth movement is essential for maintaining oral and maxillofacial stability post-treatment. Although clear aligners rely on pre-treatment digital models, their effect on periodontal hard tissues remains uncertain. By integrating CBCT-derived cervical and root data with crown data from digital intraoral scans, a three-dimensional (3D) fusion model may enhance precision and safety.

View Article and Find Full Text PDF

Bayesian Analysis Reveals the Key to Extracting Pair Potentials from Neutron Scattering Data.

J Phys Chem Lett

December 2024

Department of Chemical Engineering, University of Utah, Salt Lake City, Utah 84112, United States.

Learning interaction potentials from the structure factor is frequently seen as impractical due to accuracy constraints of neutron and X-ray scattering experiments. This study reexamines this historic inverse problem using Bayesian inference and probabilistic machine learning on a Mie fluid to elucidate how measurement noise impacts the accuracy of recovered potentials. To perform reliable potential reconstruction, we recommend that scattering data must have noise smaller than 0.

View Article and Find Full Text PDF

Comparison of Performance for Cochlear-Implant Listeners Using Audio Processing Strategies Based on Short-Time Fast Fourier Transform or Spectral Feature Extraction.

Ear Hear

December 2024

Laboratorio de Audición Computacional y Piscoacústica, Instituto de Neurociencias de Castilla y León, Universidad de Salamanca, Salamanca, Spain.

Objectives: We compared sound quality and performance for a conventional cochlear-implant (CI) audio processing strategy based on short-time fast-Fourier transform (Crystalis) and an experimental strategy based on spectral feature extraction (SFE). In the latter, the more salient spectral features (acoustic events) were extracted and mapped into the CI stimulation electrodes. We hypothesized that (1) SFE would be superior to Crystalis because it can encode acoustic spectral features without the constraints imposed by the short-time fast-Fourier transform bin width, and (2) the potential benefit of SFE would be greater for CI users who have less neural cross-channel interactions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!