Large bore accesses refer to accesses with a diameter of 10 French or greater and are necessary for various medical devices, including those used in transcatheter aortic valve replacement, endovascular aneurysm repair stent-grafts, and percutaneous mechanical support devices. Notably, the utilization of these devices via femoral access is steadily increasing due to advancements in technology and implantation techniques, which are expanding the pool of patients suitable for percutaneous procedures. However, procedures involving large bore devices carry a high risk of bleeding and vascular complications (VCs), impacting both morbidity and long-term mortality. In this review article, we will first discuss the incidence, determinants, and prognostic impact of VCs in patients undergoing large bore access procedures. Subsequently, we will explore the strategies developed in recent years to minimize VCs, including techniques for optimizing vascular puncture through femoral cannulation, such as the use of echo-guided access cannulation and fluoroscopic guidance. Additionally, we will evaluate existing vascular closure devices designed for large bore devices. Finally, we will consider new pharmacological strategies aimed at reducing the risk of periprocedural access-related bleeding.

Download full-text PDF

Source
http://dx.doi.org/10.2174/0115701611233184231206100222DOI Listing

Publication Analysis

Top Keywords

large bore
16
patients undergoing
8
bore devices
8
devices
7
strategies minimize
4
access
4
minimize access
4
access site-related
4
site-related complications
4
complications patients
4

Similar Publications

Transcatheter mass extraction of left-sided cardiac masses has gained popularity in recent years, with scarce data on effectiveness, safety, and types of devices used. Mostly, left-sided aspirations use mechanical and continuous-flow-mediated devices (the AngioVac [AngioDynamics] and Penumbra systems [Penumbra]). To our knowledge, the use of manual aspiration devices has not been reported yet.

View Article and Find Full Text PDF

We report the case of a previously independent 82-year-old female who experienced acute hemodynamic and respiratory deterioration requiring inotropic support due to a fat embolism during revision hip arthroplasty. Computed tomography pulmonary angiography demonstrated fat embolism, and transesophageal echocardiogram showed evidence of right ventricle strain and fat embolism in-transit in the right heart, as well as a moderate patent foramen ovale. Under transesophageal echocardiogram and intravascular ultrasound guidance, the Inari FlowTriever thrombectomy device was used successfully to retrieve the fat embolism with immediate hemodynamic improvement, no complications, and uneventful recovery.

View Article and Find Full Text PDF

Safety of accessing brachial veins for large-bore upper extremity venous thrombectomy using ClotTriever Thrombectomy System.

CVIR Endovasc

January 2025

Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.

Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (<ā€‰6-mm).

Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (nā€‰=ā€‰3) were excluded.

View Article and Find Full Text PDF

Objective: In-bore MRI-guided biopsy allows direct visualization of suspicious lesions, biopsy needles, and trajectories, allowing accurate sampling when MRI-ultrasound fusion biopsy is not feasible. However, its use has been limited. Wide-bore, lower-field, and lower-cost scanners could help address these issues, but their feasibility for prostate biopsy is unknown.

View Article and Find Full Text PDF

Purpose: To describe the downsizing post-closure technique for access hemostasis during emergency endovascular repair (EVAR) in ruptured abdominal aortic aneurysms (RAAA).

Materials And Methods: A cohort of eight patients underwent emergency EVAR through 16 femoral access sites for infrarenal RAAA. The downsizing post-closure technique, which involves a reduction in the size of the large-bore access by advancing a 10F sheath, was consistently applied.

View Article and Find Full Text PDF