Calibrating GESPECOR model of computing the full-energy peak efficiency of coaxial high-purity germanium detectors by Monte Carlo simulation.

Appl Radiat Isot

Mirion Technologies, 800 Research Parkway, Meriden, CT, 06450, USA.

Published: February 2024

In this work, a classical approach was used for calibrating the GESPECOR detector model for computing the full-energy peak efficiency of p-type coaxial HPGe detectors that is based on the use of linear least squares optimization. The key element of the work is the multiplicative model developed for approximating the values of the full-energy peak efficiency provided by GESPECOR code. It was linearized using the logarithmic transformation to allow an easy use of the linear least squares optimization. A procedure was also developed to estimate the optimal values of the parameters, describing the p-type coaxial HPGe detectors. Its application to a Canberra detector GC3018 showed that it is possible to determine accurate values of the full-energy peak efficiency computed by GESPECOR code using the optimized parameter values.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2023.111135DOI Listing

Publication Analysis

Top Keywords

full-energy peak
16
peak efficiency
16
calibrating gespecor
8
model computing
8
computing full-energy
8
p-type coaxial
8
coaxial hpge
8
hpge detectors
8
linear squares
8
squares optimization
8

Similar Publications

Searches for new physics below twice the electron mass with GERDA.

Eur Phys J C Part Fields

September 2024

Institute of Physics, Jagiellonian University, Cracow, Poland.

Unlabelled: A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (Gerda) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.

View Article and Find Full Text PDF

The current study proposes a procedure to estimate the activity concentration of natural radionuclides and to optimize passive shielding solutions for HPGe detectors using adjoint Monte Carlo (MC) simulation technique of Geant4 for the first time. The background spectrum is acquired for 1.56 × 10 s using an HPGe detector model (GC3020), set inside a shielding solution, during 2021-2022 to estimate the activity concentration of natural radionuclides inside the shielding.

View Article and Find Full Text PDF

A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.

View Article and Find Full Text PDF

Temperature drift during environmental radiation monitoring and its unfolding.

Appl Radiat Isot

April 2024

Central Laboratory for Radiological Protection, Konwaliowa 7 Str. 03-194 Warsaw, Poland.

The aim of the presented paper is to examine the temperature drift and its unfolding for an environmental monitor equipped with a LaBr(Ce) detector. It is known that temperature could influence energy, shape, and efficiency calibration. Consequently, when ambient temperature changes, the full energy absorption peak moves in the resulting spectrum.

View Article and Find Full Text PDF

Integrated absolute full energy peak efficiency: A measure of photon registration efficiency.

Appl Radiat Isot

April 2024

Institute of Agrophysics, Polish Academy of Sciences, Doswiadczalna 4, 20-290, Lublin, Poland. Electronic address:

Integrated absolute full energy peak efficiency (IAFEPE) is a measure of photon registration efficiency using the γ-ray spectrometry method. We have derived appropriate formulas and theoretical explanations of IAFEPE for the first time. IAFEPE is a definite integral (Riemann integral) of the photon registration efficiency function within the detection energy range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!