Ultrasound tissue scatterer distribution imaging: An adjunctive diagnostic tool for shear wave elastography in characterizing focal liver lesions.

Ultrason Sonochem

Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Division of Pediatric Gastroenterology, Department of Pediatrics, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Liver Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Research Center for Radiation Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address:

Published: December 2023

Objectives: Focal liver lesion (FLL) is a prevalent finding in cross-sectional imaging, and distinguishing between benign and malignant FLLs is crucial for liver health management. While shear wave elastography (SWE) serves as a conventional quantitative ultrasound tool for evaluating FLLs, ultrasound tissue scatterer distribution imaging (TSI) emerges as a novel technique, employing the Nakagami statistical distribution parameter to estimate backscattered statistics for tissue characterization. In this prospective study, we explored the potential of TSI in characterizing FLLs and evaluated its diagnostic efficacy with that of SWE.

Methods: A total of 235 participants (265 FLLs; the study group) were enrolled to undergo abdominal examinations, which included data acquisition from B-mode, SWE, and raw radiofrequency data for TSI construction. The area under the receiver operating characteristic curve (AUROC) was used to evaluate performance. A dataset of 20 patients (20 FLLs; the validation group) was additionally acquired to further evaluate the efficacy of the TSI cutoff value in FLL characterization.

Results: In the study group, our findings revealed that while SWE achieved a success rate of 49.43 % in FLL measurements, TSI boasted a success rate of 100 %. In cases where SWE was effectively implemented, the AUROCs for characterizing FLLs using SWE and TSI stood at 0.84 and 0.83, respectively. For instances where SWE imaging failed, TSI achieved an AUROC of 0.78. Considering all cases, TSI presented an overall AUROC of 0.81. There was no statistically significant difference in AUROC values between TSI and SWE (p > 0.05). In the validation group, using a TSI cutoff value of 0.67, the AUROC for characterizing FLLs was 0.80.

Conclusions: In conclusion, ultrasound TSI holds promise as a supplementary diagnostic tool to SWE for characterizing FLLs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10755484PMC
http://dx.doi.org/10.1016/j.ultsonch.2023.106716DOI Listing

Publication Analysis

Top Keywords

characterizing flls
16
tsi
11
ultrasound tissue
8
tissue scatterer
8
scatterer distribution
8
distribution imaging
8
diagnostic tool
8
shear wave
8
wave elastography
8
focal liver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!