AI Article Synopsis

  • A screening tool for obstructive sleep apnoea (OSA) was evaluated in an African population to determine its effectiveness compared to objective sleep recordings.
  • The study involved 1810 participants who underwent respiratory polygraphy and completed various OSA screening questionnaires, with scores being measured against the severity categories of OSA defined by their apnoea-hypopnoea index.
  • Results indicated that while all screening scores had low positive predictive values, the NoSAS8 score showed the best performance and is recommended for use in low-resource settings for OSA screening.

Article Abstract

Introduction: A screening tool for obstructive sleep apnoea (OSA) is useful in low-income countries where it may be difficult to access sleep recordings. The objective of this study was to assess the performance of six screening scores compared with objective sleep recording in an African population sample.

Methods: This analysis is based on the "Benin Sleep and Society" (BeSAS) populational study in which respiratory polygraphy (PG) was performed using a type III device and OSA screening questionnaires (STOP, STOP-Bang, Berlin, NOSAS [≥ 8 and ≥ 5), No-Apnea, GOAL) were administered to participants. PG-defined OSA severity categories were defined according to the apnoea-hypopnoea index (AHI): mild (AHI 5 to <15/h), moderate (AHI 15 to <30/h) or severe (AHI≥30/h), and these were compared to score findings.

Results: A total of 1810 subjects (mean age 45.4±14.6 years; 57.3% women) were included. For moderate to severe OSA, the area under the receiving operating characteristic (ROC) curve was greatest for GOAL and No-Apnea (0.70), followed by NoSAS5 (0.69). The highest sensitivity values were for NoSAS5 (0.73), No-Apnea (0.72), and GOAL (0.69), while NoSAS8 had the highest specificity (0.91), followed by Berlin (0.88) and GOAL (0.71). All scores performed poorly with respect to the positive predictive value (PPV), which was highest with NoSAS8 (0.38). Conclusion: This study provides the first comparison of the performance of screening scores for OSA in an African population. Although still low, PPV was highest with NoSAS8. Hence, NoSAS8 would be the screening method of choice for OSA in resource-constrained settings where formal sleep recordings are not accessible.

Download full-text PDF

Source

Publication Analysis

Top Keywords

performance screening
8
screening scores
8
obstructive sleep
8
sleep apnoea
8
african population
8
sleep
5
scores obstructive
4
apnoea african
4
population introduction
4
introduction screening
4

Similar Publications

Prognostic Value of Myocardial CT-ECV in Severe Aortic Stenosis Requiring Aortic Valve Replacement: A Systematic Review and Meta-analysis.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy.

Aim: Computed tomography (CT)-derived extracellular volume fraction (ECV) is a non-invasive method to quantify myocardial fibrosis. Evaluating CT-ECV during aortic valve replacement (AVR) planning CT in severe aortic stenosis (AS) may aid prognostic stratification. This meta-analysis evaluated the prognostic significance of CT-ECV in severe AS necessitating AVR.

View Article and Find Full Text PDF

Background: Intensive care units (ICUs) handle the most critical patients with a high risk of mortality. Due to those conditions, close monitoring is necessary and therefore, a large volume of data is collected. Collaborative ventures have enabled the emergence of large open access databases, leading to numerous publications in the field.

View Article and Find Full Text PDF

Purpose: Recent advances in artificial intelligence provide opportunities to capture and represent complex features of human language in a more automated manner, offering potential means of improving the efficiency of language assessment. This review article presents computerized approaches for the analysis of narrative language and identification of language disorders in children.

Method: We first describe the current barriers to clinicians' use of language sample analysis, narrative language sampling approaches, and the data processing stages that precede analysis.

View Article and Find Full Text PDF

In silico drug repurposing at the cytoplasmic surface of human aquaporin 1.

PLoS One

January 2025

Genome and Structural Bioinformatics Group, Faculty of Medicine, Health and Life Science, Swansea University, Swansea, Wales, United Kingdom.

Aquaporin 1 (AQP1) is a key channel for water transport in peritoneal dialysis. Inhibition of AQP1 could therefore impair water transport during peritoneal dialysis. It is not known whether inhibition of AQP1 occurs unintentionally due to off-target interactions of administered medications.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate the diagnostic value of standardized semiquantitative scoring of color Doppler ultrasound combined with liver stiffness measurement (LSM) of sound touch elastography (STE) in chronic hepatitis B (CHB) patients, providing a reference for the liver fibrosis diagnosis.

Methods: We performed ultrasound and STE on CHB patients, with liver biopsies as the benchmark. We compared the differences in ultrasound standardized semiquantitative scoring and LSM among patients with different stages of liver fibrosis, and evaluated the diagnostic efficacy of significant liver fibrosis using receiver operating characteristic (ROC) curves and the area under the ROC curve alone or in combination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!