All-suture fixation of syndesmotic injuries: a case series.

Eur J Orthop Surg Traumatol

Medical Group of the Carolinas, Spartanburg, SC, 29307, USA.

Published: April 2024

Background: To retrospectively evaluate the clinical outcomes of patients treated for syndesmotic injuries with an all-suture construct technique and compare their patient reported outcome scores with historically published outcomes of syndesmotic injuries fixed with suspensory suture buttons.

Methods: This was a retrospective case series of patients treated at a Level 1 Trauma Center from May 1, 2018, to June 30, 2022. Ten patients aged 18 and older with unstable syndesmotic injuries treated with all-suture repair. Patients were excluded if they were treated with trans-osseous screws, had previous failed syndesmotic fixation, or suspensory suture button fixation. Patient-reported outcomes including Visual Analog Scale (VAS) pain scores, American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot scores, and complications were recorded.

Results: In the patients with 6 weeks or more of radiographic follow-up (N = 9), there was no evidence of nonunion, loss of fixation, hardware complication, or whitling of the fibula by the suture. At final follow-up average VAS pain scores were 1.5 out of 10 (range 0-4; SD 1.2), AOFAS ankle and hindfoot scores averaged 89.6 out of 100 (range 86-100; SD 6.1). The pain subscale of the AOFAS score averaged 37.5 out of 40 (range 35-40; SD 2.5). The functional subscale of the AOFAS score averaged 46 out of 50 (range 44-50; SD 3.0). Stiffness was reported in one patient at their follow-up visits, which resolved with continued physical therapy. There were no superficial or deep infections.

Conclusions: In conclusion, this case series presents the first clinical outcomes of an all-suture fixation technique for treatment of unstable syndesmotic ankle injuries. Our results suggest that the all-suture fixation technique results in similar patient reported outcomes when compared with historically reported patient reported outcomes of suspensory suture button fixation, and low rates of complication or hardware failure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-023-03797-3DOI Listing

Publication Analysis

Top Keywords

syndesmotic injuries
16
all-suture fixation
12
case series
12
patient reported
12
suspensory suture
12
clinical outcomes
8
patients treated
8
injuries all-suture
8
unstable syndesmotic
8
suture button
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!