The Interpretation of Standard Cardiopulmonary Exercise Test Indices of Cardiac Function in Chronic Kidney Disease.

J Clin Med

Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds LS2 9JT, UK.

Published: December 2023

Background And Aims: As there is growing interest in the application of cardiopulmonary exercise test (CPX) in chronic kidney disease (CKD), it is important to understand the utility of conventional exercise test parameters in quantifying the cardiopulmonary fitness of patients with CKD. Merely extrapolating information from heart failure (HF) patients would not suffice. In the present study, we evaluated the utility of CPX parameters such as the peak O-pulse and the estimated stroke volume (SV) in assessing the peak SV by comparing with the actual measured values. Furthermore, we compared the anaerobic threshold (AT), peak circulatory power, and ventilatory power with that of the measured values of the peak cardiac power (CPO) in representing the cardiac functional reserve in CKD. We also performed such analyses in patients with HF for comparison.

Method: A cross sectional study of 70 asymptomatic male CKD patients [CKD stages 2-5 (pre-dialysis)] without primary cardiac disease or diabetes mellitus and 25 HF patients. A specialized CPX with a CO rebreathing technique was utilized to measure the peak cardiac output and peak cardiac power output. The peak O consumption (VO) and AT were also measured during the test. Parameters such as the O-pulse, stroke volume, arteriovenous difference in O concentration [C(a-v)O], peak circulatory power, and peak ventilatory power were all calculated. Pearson's correlation, univariate, and multivariate analyses were applied.

Results: Whereas there was a strong correlation between the peak O-pulse and measured peak SV in HF, the correlation was less robust in CKD. Similarly, the correlation between the estimated SV and the measured SV was less robust in CKD compared to HF. The AT only showed a modest correlation with the CPO in HF and only a weak correlation in CKD. A stronger correlation was demonstrated between the peak circulatory power and CPO, and the ventilatory power and CPO. In HF, the central cardiac factor was the predominant determinant of the standard CPX-derived surrogate indices of cardiac performance. By contrast, in CKD both central and peripheral factors played an equally important role, making such indices less reliable markers of cardiac performance per se in CKD.

Conclusion: The results highlight that the standard CPX-derived surrogate markers of cardiac performance may be less reliable in CKD, and that further prospective studies comparing such surrogate markers with directly measured cardiac hemodynamics are required before adopting such markers into clinical practice or research in CKD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10707285PMC
http://dx.doi.org/10.3390/jcm12237456DOI Listing

Publication Analysis

Top Keywords

exercise test
12
peak
12
peak circulatory
12
circulatory power
12
ventilatory power
12
peak cardiac
12
power cpo
12
cardiac performance
12
cardiac
11
ckd
10

Similar Publications

Background: Sarcopenia is closely associated with a poor quality of life and mortality, and its prevention and treatment represent a critical area of research. Resistance training is an effective treatment for older adults with sarcopenia. However, they often face challenges when receiving traditional rehabilitation treatments at hospitals.

View Article and Find Full Text PDF

Background: University students in Saudi Arabia are embracing some of the negative traits of the fast-paced modern lifestyle, typified by unhealthy eating, low physical activity, and poor sleep habits that may increase their risk for poor health. Health and holistic well-being at the population level are among the priorities of the 2030 vision of a vibrant society in the Kingdom of Saudi Arabia. The current study thus aims at determining the prevalence and predictive factors of Suboptimal Health Status (SHS) among university students.

View Article and Find Full Text PDF

Purpose: To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.

Methods: Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0-15%) at 26.

View Article and Find Full Text PDF

Police tactical group (PTG) officers respond to the most demanding and high-risk police situations. As such, PTG personnel require exceptional physical fitness, and selection for employment often evaluates fitness both directly and indirectly. While heart rate (HR) is often used to measure physical effort, heart rate variability (HRV) may be a valuable tool for measuring stress holistically.

View Article and Find Full Text PDF

We examined the reliability and validity of the Brief Physical Activity Assessment Tool (BPAAT) when administered by telephone interview compared to in-person administration. We analyzed data from the Epi-asthma study. Adult participants registered in the participating Portuguese primary health care centres (PCC) completed the BPAAT via telephone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!