This study evaluates intracochlear electrocochleography (ECochG) for real-time monitoring during cochlear implantation. One aim tested whether adjusting the recording electrode site would help differentiate between atraumatic and traumatic ECochG amplitude decrements. A second aim assessed whether associations between ECochG amplitude decrements and post-operative hearing loss were weaker when considering hearing sensitivity at the ECochG stimulus frequency compared to a broader frequency range. Eleven adult cochlear implant recipients who were candidates for electro-acoustic stimulation participated. Single-frequency (500-Hz) ECochG was performed during cochlear implantation; the amplitude of the first harmonic of the difference waveform was considered. Post-operative hearing preservation at 500 Hz ranged from 0 to 94%. The expected relationship between ECochG amplitude decrements and hearing preservation was observed, though the trend was not statistically significant, and predictions were grossly inaccurate for two participants. Associations did not improve when considering alternative recording sites or hearing sensitivity two octaves above the ECochG stimulus frequency. Intracochlear location of a moving recording electrode is a known confound to real-time interpretation of ECochG amplitude fluctuations, which was illustrated by the strength of the correlation with ECochG amplitude decrements. Multiple factors contribute to ECochG amplitude patterns and to hearing preservation; these results highlight the confounding influence of intracochlear recording electrode location on the ECochG.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10707171PMC
http://dx.doi.org/10.3390/jcm12237409DOI Listing

Publication Analysis

Top Keywords

ecochg amplitude
24
amplitude decrements
16
recording electrode
12
hearing preservation
12
ecochg
11
intracochlear electrocochleography
8
cochlear implant
8
cochlear implantation
8
post-operative hearing
8
hearing sensitivity
8

Similar Publications

Background: The aim of this study was to relate response patterns of electrocochleography (ECochG) recordings during cochlear implantation to pre- and postoperative hearing.

Methods: Thirty subjects with either flat (FA, n = 9) or sloping (SA, n = 21) audiograms before cochlear implantation were prospectively included. Real-time ECochG recordings were conducted via the cochlear implant.

View Article and Find Full Text PDF

Stimulus Rate Effect on Electrocochleogram Components in Adults with High Risk for Noise Exposure.

J Am Acad Audiol

January 2024

Dpartment of Communication Sciences and Disorders, Missouri State University, Springfield, Missouri.

Background:  Hidden hearing loss (HHL) is a newly described condition that has been associated with hearing thresholds within normal limits and poorer speech-in-noise (SIN) performance. Furthermore, HHL has been associated with an elevated or absent middle ear muscle reflex (MEMR). One of the leading factors causing HHL is exposure to noise, specifically in patients who experience temporary threshold shift.

View Article and Find Full Text PDF

Objective: This study examined patients with normal hearing thresholds who had trouble understanding speech in noise. We used electrocochleography (ECochG) to detect and compare SP/AP amplitude area ratios, a potential indicator of cochlear synaptopathy, and investigate speech perception disorder in noise.

Methods: The study included 68 people aged between 18 and 65 years, 35 patients and 33 healthy volunteers, who applied to the otorhinolaryngology clinic between November 2023 and March 2024 with a 2-month history of difficulty understanding speech in noisy environments.

View Article and Find Full Text PDF

Wireless electrocochleography in awake chinchillas: A model to study crossmodal modulations at the peripheral level.

Hear Res

September 2024

Departamento de Patología Animal, Facultad de Ciencias Veterinarias y Pecuarias, Universidad de Chile 8820808, Santiago, Chile. Electronic address:

The discovery and development of electrocochleography (ECochG) in animal models has been fundamental for its implementation in clinical audiology and neurotology. In our laboratory, the use of round-window ECochG recordings in chinchillas has allowed a better understanding of auditory efferent functioning. In previous works, we gave evidence of the corticofugal modulation of auditory-nerve and cochlear responses during visual attention and working memory.

View Article and Find Full Text PDF

Objectives: The inter-phase gap (IPG) offset effect is defined as the dB offset between the linear parts of electrically evoked compound action potential (ECAP) amplitude growth functions for two stimuli differing only in IPG. The method was recently suggested to represent neural health in cochlear implant (CI) users while being unaffected by CI electrode impedances. Hereby, a larger IPG offset effect should reflect better neural health.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!