Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Three-dimensional (3D) porous graphene-based materials have displayed attractive electrochemical catalysis and sensing performances, benefiting from their high porosity, large surface area, and excellent electrical conductivity. In this work, a novel electrochemical sensor based on 3D porous reduced graphene (3DPrGO) and ion-imprinted polymer (IIP) was developed for trace cadmium ion (Cd(II)) detection in water. The 3DPrGO was synthesized in situ at a glassy carbon electrode (GCE) surface using a polystyrene (PS) colloidal crystal template and the electrodeposition method. Then, IIP film was further modified on the 3DPrGO by electropolymerization to make it suitable for detecting Cd(II). Attributable to the abundant nanopores and good electron transport of the 3DPrGO, as well as the specific recognition for Cd(II) of IIP, a sensitive determination of trace Cd(II) at PoPD-IIP/3DPrGO/GCE was achieved. The proposed sensor exhibited comprehensive linear Cd(II) responses ranging from 1 to 100 μg/L (R2 = 99.7%). The limit of detection (LOD) was 0.11 μg/L, about 30 times lower than the drinking water standard set by the World Health Organization (WHO). Moreover, PoPD-IIP/3DPrGO/GCE was applied for the detection of Cd(II) in actual water samples. The satisfying recoveries (97-99.6%) and relative standard deviations (RSD, 3.5-5.7%) make the proposed sensor a promising candidate for rapid and on-site water monitoring.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10708675 | PMC |
http://dx.doi.org/10.3390/s23239561 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!