A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of Low-Cost IoT System for Monitoring Piezometric Level and Temperature of Groundwater. | LitMetric

Rural communities in Mexico and other countries with limited economic resources require a low-cost measurement system for the piezometric level and temperature of groundwater for their sustainable management, since anthropogenic action (pumping extractions), natural recharge and climate change phenomena affect the behavior of piezometric levels in the aquifer and its sustainability is at risk. Decrease in the piezometric level under a balanced level promotes salt intrusion from ocean water to the aquifer, salinizing and deteriorating the water quality for agriculture and other activities; and a decrease in water level under the pumps or well drilling depth could deprive communities of water. Water temperature monitoring is essential to determine electric conductivity and dissolved salt content in groundwater. Using IoT technology, a device was developed that monitors both variables inside the well, and the ambient temperature and atmospheric pressure outside the well. The measurements are made in real time, with sampling every second and sending data to a dedicated server every 15 min so that the visualization can be accessed through a device with Internet access. The time series of the variables measured inside and outside the well were obtained over a period of three months in the rural community of Agua Blanca, Guasave, Sinaloa, Mexico. Through these records, a progressive temporary drawdown of the piezometric level is observed, as well as the frequency of pumping. This low-cost IoT system shows potential use in hydrological processes of interest such as the separation of regional and local flow, drawdown rates and recognition of geohydrological parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10708790PMC
http://dx.doi.org/10.3390/s23239364DOI Listing

Publication Analysis

Top Keywords

piezometric level
16
low-cost iot
8
iot system
8
level temperature
8
temperature groundwater
8
inside well
8
level
6
piezometric
5
water
5
well
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!