Background: Dynamic glucose-enhanced (DGE) chemical exchange saturation transfer (CEST) has the potential to characterize glucose metabolism in brain metastases. Since the effect size of DGE CEST is small at 3 T (< 1%), measurements of signal-to-noise ratios are challenging. To improve DGE detection, we developed an acquisition pipeline and extended image analysis for DGE CEST on a hybrid 3-T positron emission tomography/magnetic resonance imaging system.
Methods: This cross-sectional study was conducted after local ethical approval. Static Z-spectra (from -100 to 100 ppm) were acquired to compare the use of 1.2 versus 2 ppm to calculate static glucose-enhanced (glucoCEST) maps in 10 healthy volunteers before and after glucose infusion. Dynamic CEST images were acquired during glucose infusion. Image analysis was optimized using motion correction, dynamic B correction, and principal component analysis (PCA) to improve the detection of DGE CEST in the sagittal sinus, cerebrospinal fluid, and grey and white matter. The developed DGE CEST pipeline was applied to four patients diagnosed with brain metastases.
Results: GlucoCEST was strongest in healthy tissues at 2 ppm. Correcting for motion, B and use of PCA locally improved DGE maps. A larger contrast between healthy tissues and enhancing regions in brain metastases was found when dynamic B correction and PCA denoising were applied.
Conclusion: We demonstrated the feasibility of DGE CEST with our developed acquisition and analysis pipeline at 3 T in patients with brain metastases. This work enables a direct comparison of DGE CEST to 18F-fluoro-deoxy-D-glucose positron emission tomography of glucose metabolism in patients with brain metastases.
Relevance Statement: Contrast between brain metastasis and healthy brain tissue in DGE CEST MR images is improved by including principle component analysis and dynamic magnetic field correction during postprocessing. This approach enables the detection of increased DGE CEST signal in brain metastasis, if present.
Key Points: • Despite the low signal-to-noise ratio, dynamic glucose-enhanced CEST MRI is feasible at 3 T. • Principal component analyses and dynamic magnetic field correction improve DGE CEST MRI. • DGE CEST MRI does not consequently show changes in brain metastases compared to healthy brain tissue. • Increased DGE CEST MRI in brain metastases, if present, shows overlap with contrast enhancement on T1-weighted images.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10709288 | PMC |
http://dx.doi.org/10.1186/s41747-023-00390-5 | DOI Listing |
ArXiv
October 2024
F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, US.
NMR Biomed
January 2025
Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
The study aimed to investigate the feasibility of dynamic glucose-enhanced (DGE) MRI technology in the clinical application of glioma. Twenty patients with glioma were examined using a preoperative DGE-MRI protocol before clinical intervention. A brief hyperglycemic state was achieved by injecting 50 mL of 50% w/w D-glucose intravenously during the DGE imaging.
View Article and Find Full Text PDFEnviron Sci Technol
October 2024
Department of Environmental Science and Engineering, Institute of Atmospheric Sciences, Fudan University, Shanghai 200438, China.
Soil contamination by multiple metals is a significant concern due to the interlinked mobilization processes. The challenges in comprehending this issue arise from the poorly characterized interaction among different metals and the complexities introduced by spatial and temporal heterogeneity in soil systems. We delved into these complexities by incubating size-fractionated paddy soils under both anaerobic and aerobic conditions, utilizing a combination of techniques for aqueous and colloidal analysis.
View Article and Find Full Text PDFJCI Insight
October 2024
Division of Neurobiology, Department of Psychiatry and Behavioral Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
The accumulation of mutant huntingtin protein aggregates in neurons is a pathological hallmark of Huntington's disease (HD). The glymphatic system, a brain-wide perivascular network, facilitates the exchange of interstitial fluid and cerebrospinal fluid (CSF), supporting interstitial solute clearance of brain wastes. In this study, we employed dynamic glucose-enhanced (DGE) MRI to measure d-glucose clearance from CSF as a tool to predict glymphatic function in a mouse model of HD.
View Article and Find Full Text PDFBioresour Technol
June 2024
School of Resources, Environment and Materials, Guangxi University, No. 100 Daxue Road, Nanning, Guangxi 530004, China; Key Laboratory of Environmental Protection (Guangxi University), Education Department of Guangxi Zhuang Autonomous Region, Guangxi Nanning 530004, China; Guangxi Key Laboratory of Emerging Contaminants Monitoring, Early Warning and Environmental Health Risk Assessment. Electronic address:
This study investigated the influence of yeast extract addition, carbon source, and photoperiod on the growth dynamics of Auxenochlorella pyrenoidosa FACHB-5. Employing response surface methodology, the culture strategy was optimized, resulting in the following optimal conditions: yeast extract addition at 0.75 g L, glucose concentration of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!