A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Near-infrared fluorescent probe with large Stokes shift for specific detection of lysine. | LitMetric

Near-infrared fluorescent probe with large Stokes shift for specific detection of lysine.

Spectrochim Acta A Mol Biomol Spectrosc

College of Chemistry and Chemical Engineering, Donghua University, Shanghai 201620, China. Electronic address:

Published: March 2024

A new near-infrared (NIR) fluorescent probe CL based on coumarin- dicyanoisophorone was synthesized. Addition of Lys to probe CL solution in DMF/HO (9:1, v/v) medium resulted in noticeable enhancement in the intensity of the fluorescence emission at 702 nm, accompanying distinct color change from yellow to pink. While addition of other amino acids and biothiols (Gly, Hcy, GSH, Glu, Val, Tyr, Arg, Trp, Lys, His, Leu, Phe, Asp and Met) did not bring about substantial changes in both fluorescence emission and color. The detection limit was calculated to be 0.51 μM. Job's plot test revealed that probe CL and Lys formed a complex of 1:1 stoichiometry. Probe CL showed high stability and could be used to recognize Lys in a wide pH range of 4.0-10.0. The sensing mechanism was proposed and verified by H NMR spectral measurement. The dual-modal fluorescence turn-on and colorimetric NIR probe with an extremely large Stokes shift of 280 nm may be utilized for highly specific and practical sensing of Lys.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123734DOI Listing

Publication Analysis

Top Keywords

fluorescent probe
8
large stokes
8
stokes shift
8
fluorescence emission
8
probe
6
lys
5
near-infrared fluorescent
4
probe large
4
shift specific
4
specific detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!