The understanding of amorphous and heterojunction materials has been widely used in the field of electromagnetic wave absorption due to their unique physical and chemical properties. However, the effectiveness of individual strategies currently used is still limited. Well-designed compositions and amorphous structures simplify the effect of different polarization mechanisms on the absorption of electromagnetic waves. In this work, through the carbonization and controlled phosphating of one-dimensional Co Metal-Organic Framework (Co-MOF) nanorods, the synthesis of complex components and amorphous CoP with phosphorus vacancies is successfully accomplished, thus adjusting the optimization of electromagnetic parameters. Phosphorus-vacancy-induced defective polarization loss and enhanced-electronegativity-differences-induced dipole polarization loss synergistically as a dual-polarization strategy significantly improved the electromagnetic parameters and impedance matching. In conclusion, the electromagnetic parameters of the Co@CoP@C composites are indeed significantly regulated, with reflection losses of -55 dB and a bandwidth of up to 5.5 GHz. These innovative research ideas provide instructive thinking for the development of amorphous absorbers with vacancies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10708327PMC
http://dx.doi.org/10.3390/nano13233025DOI Listing

Publication Analysis

Top Keywords

electromagnetic parameters
16
phosphorus vacancies
8
electromagnetic wave
8
polarization loss
8
electromagnetic
6
amorphous
5
tuning electromagnetic
4
parameters
4
parameters induced
4
induced synergistic
4

Similar Publications

Noninvasive High-Intensity Focused Electromagnetic Therapy in Women With Urinary Incontinence: A Systematic Review and Meta-Analysis.

Neurourol Urodyn

January 2025

Department of Surgery, Division of Urology, Persahabatan General Hospital-Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.

Introduction: Urinary incontinence (UI) is an uncontrollable expulsion of urine at a time. UI is obviously not life-threatening, but its impact on the patient's quality of life (QoL) is often devastating. Many treatments method to address this problem but all these methods have limitations.

View Article and Find Full Text PDF

Including sensor information in medical interventions aims to support surgeons to decide on subsequent action steps by characterizing tissue intraoperatively. With bladder cancer, an important issue is tumor recurrence because of failure to remove the entire tumor. Impedance measurements can help to classify bladder tissue and give the surgeons an indication on how much tissue to remove.

View Article and Find Full Text PDF

Fano Resonance in Epsilon-Near-Zero Media.

Phys Rev Lett

December 2024

Department of Electronic Engineering, Tsinghua University, Beijing 100084, China.

Fano resonance is achieved by tuning two coupled oscillators and has exceptional potential for modulating light dispersion. Here, distinct from the classical Fano resonances achieved through photonics methodologies, we introduce the Fano resonance in epsilon-near-zero (ENZ) media with novel electromagnetic properties. By adjusting the background permeability of the ENZ host, the transmission spectrum exhibits various dispersive line shapes and covers the full range of Fano parameter q morphologies, from negative to positive infinity.

View Article and Find Full Text PDF

Background: This study aims to determine the impact of laptop and tablet use on total motile sperm count (TMSC) in men being investigated for assisted reproduction.

Methods: A cross-sectional study was conducted on 156 men attending a fertility clinic in Jamaica. Routine semen analyses were performed and parameters specific to TMSC assessed.

View Article and Find Full Text PDF

Background: Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).

Methods: Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!