To investigate the effects of the application of a low addition refractive multifocal intraocular lens (IOL) using the micromonovision design in the non-dominant eye with different degrees of preset myopia on the visual acuity, visual function and visual quality after bilateral cataract surgery. In this randomized controlled trial, patients who were proposed to undergo bilateral phacoemulsification combined with rotational asymmetric refractive IOL (MF15 IOL) implantation at the First Affiliated Hospital of Zhengzhou University between September 2020 and August 2022 were included. All patients were divided into three groups using the random number method. The target refraction of the IOL in the dominant eye was 0.00 D. Non-dominant eyes were given different preoperative IOL reserve refractions, with the reserved near additional degree>0.20 D and≤0.40 D as the low addition,>0.40 D and≤0.60 D as the medium addition, and>0.60 D and≤0.80 D as the high addition. We compared uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) of monocular and binocular eyes at 1 day, 1 month and 3 months postoperatively in the 3 groups of patients. Furthermore, the contrast sensitivity, stereopsis, defocus curves and visual quality questionnaire results of binocular eyes were compared at 3 months postoperatively. The statistical methods mainly used were chi-square test, two-factor repeated measures ANOVA, one-way ANOVA, LSD test, Kruskal-Wallis test, and paired -test. A total of 110 patients (220 eyes) were enrolled in the study, including 48 males and 62 females, with an average age of (59.74±9.38) years. There were 40 patients (80 eyes) in the low additional degree group, 37 patients (74 eyes) in the medium additional degree group, and 33 patients (66 eyes) in the high additional degree group. The differences in distance, intermediate and near visual acuity of the dominant eyes among the three groups were not statistically significant at different measurement timepoints postoperatively (>0.05). The differences in intermediate and near visual acuity of the non-dominant eyes were also not statistically significant (>0.05) among the three groups. In contrast, at 3 months, the UDVA of the non-dominant eyes in the low additional degree group (0.04±0.06) and medium additional degree group (0.04±0.07) was significantly higher than that in the high additional degree group (0.08±0.09) (=4.776, =0.011, bias =0.086). There was no statistically significant difference in binocular uncorrected distance, intermediate and near visual acuity among the three groups at different postoperative timepoints (>0.05). The binocular UDVA, UIVA and UNVA (logMAR visual acuity) at 3 months postoperatively were -0.04±0.04, 0.03±0.08, 0.10±0.13 in the low addition group, -0.01±0.05, -0.02±0.06, 0.09±0.10 in the medium addition group, and 0.02±0.07, 0.01±0.09, 0.16±0.11 in the high addition group. At 3 months postoperatively, the binocular contrast sensitivity of the low additional degree group was significantly higher than that of the high additional degree group (<0.05), except that there was no significant difference at the spatial frequency of 6 cycles per degree in the absence of glare (>0.05). The binocular contrast sensitivity of the medium additional degree group was significantly higher than that of the high additional degree group at the spatial frequencies of 6 and 18 cycles per degree in the glare condition (<0.05). The difference in the binocular contrast sensitivity between the low and medium additional degree groups did not reach statistical significance (>0.05). The peak of the binocular defocus curve in the three groups was significantly wider than that in the monocular eyes, and the decline trend was more gentle, with no trough in the middle, and the visual acuity could be maintained above 0.2 (logMAR visual acuity) in the 0.00 D to -3.00 D defocus range. There was no significant difference in the postoperative near stereopsis results among the three groups (>0.05), with the percentage of near stereopsis sharpness≤60″ reaching 90.00% (36/40), 89.19% (33/37) and 78.79% (26/33), respectively. The proportions of VF-14 scores≥90 in the postoperative questionnaire were 90% (36/40), 91.89% (34/37) and 81.82% (27/33) for the low, medium and high additional degree groups, respectively. The differences in the probability of photic phenomena and spectacles-independent rate were not statistically significant (>0.05). The use of micromonovision design for bilateral implantation of a rotational asymmetric refractive MF15 IOL, with the non-dominant eye reserved for different near additional degrees, can enable cataract patients to have significantly improved binocular full-range vision, visual function and visual quality. When the degree of reserved near additions in the non-dominant eye preoperatively is>0.20 D and≤0.60 D, it can ensure sufficient binocular UDVA, UIVA and UNVA after surgery, and meanwhile help to obtain superior contrast sensitivity and stereopsis, as well as a satisfactory spectacles-independent rate and low incidence of photic phenomena.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112142-20230220-00060DOI Listing

Publication Analysis

Top Keywords

additional degree
44
visual acuity
40
degree group
40
three groups
24
high additional
20
visual quality
16
intermediate visual
16
months postoperatively
16
contrast sensitivity
16
visual
15

Similar Publications

Plastics are globally considered a significant threat, particularly to metropolitan areas, due to the extensive use of plastic products. This research is the first of its kind to document microplastics contamination and its effects on Red wettled lapwing (Vanellus indicus). The concentration of microplastics (MPs) was measured from surface water at different locations including canals and drains, which are the primary sources of MPs pollution in the metropolitan city Lahore, Pakistan.

View Article and Find Full Text PDF

Determination of the degree of sulfonation in cross-linked and non-cross-linked Poly(ether ether ketone) using different analytical techniques.

Heliyon

January 2025

Division of Polymer Chemistry, Department of Chemistry, Atomic Energy Commission, P.O. Box: 6091, Damascus, Syrian Arab Republic.

The degree of sulfonation (DS) is a key property of sulfonated polymers, as it significantly influences their swelling behaviour, conductivity and mechanical properties. Accurately determining the DS is essential for optimizing these materials for various applications. In this work, the DS of sulfonated poly (ether ether ketone) (SPEEK) was evaluated using a combination of analytical techniques, including titration, back titration, Fourier Transform Infrared (FTIR), Ultra-Violet (UV) and proton nuclear magnetic resonance (H NMR) spectroscopies, Thermogravimetric analysis (TGA), Rutherford backscattering (RBS) and particle induced X-ray emission (PIXE) analysis.

View Article and Find Full Text PDF

Earlier research and reports from educational practice seem to suggest that teaching early literacy skills may facilitate speech-sound production in students with intellectual disabilities, but further research is needed to confirm a potential connection. This study investigated (1) the relationship between speech-sound production, phonological awareness, and letter-sound knowledge in students with intellectual disabilities and communication difficulties, and (2) to what degree phonological awareness and letter-sound knowledge explain the variance in speech-sound production over and above IQ and chronological age. A group of 116 students, aged 7-21, enrolled in Swedish compulsory schools for students with intellectual disabilities participated in this study.

View Article and Find Full Text PDF

The purpose of this article, part 1 of 2 on randomised controlled trials (RCTs), is to provide readers (eg, clinicians, patients, health service and policy decision-makers) of the nutrition literature structured guidance on interpreting RCTs. Evaluation of a given RCT involves several considerations, including the potential for risk of bias, the assessment of estimates of effect and their corresponding precision, and the applicability of the evidence to one's patient. Risk of bias refers to flaws in the design or conduct of a study that may lead to a deviation from measuring the underlying true effect of an intervention.

View Article and Find Full Text PDF

Background: Activities in daily living (ADLs) disability triggered by aging population and chronic diseases in the middle-aged and older adults has become a major public health challenge. Cardiovascular-kidney-metabolic (CKM) syndrome, as a combination of several chronic conditions, has not yet been studied to explore its association with ADLs disability. We examined the association between CKM syndrome and ADLs disability among middle-aged and older adults in China and whether it varied by age and socioeconomic status.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!