Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction And Objectives: Both computed tomography (CT) and renal scintigraphy (RS) have been used to assess vascular anatomy, renal status, and split renal function (SRF). In this study, we used a recently developed software that facilitates renal volumetric evaluations to compare RS and automated CT volumetry for assessing residual renal function and, thus, estimating postoperative renal function after donor nephrectomy.
Methods: Fifty-one cases of donor nephrectomy were analyzed. Residual renal function was estimated based on RS and CT volumetry. The correlation between the postoperative estimated glomerular filtration rate (eGFR) and expected SRF, measured using RS and three types of CT volumetry data (ellipsoid, thin-slice, and 5-mm slice data), was determined.
Results: The correlation coefficient between actual eGFR and expected SRF was significantly associated at each time point and modality (p < 0.0001). At any time point, the difference in correlation coefficient between RS and 5-mm volumetry was significant (p value: 0.003-0.018), whereas the differences in correlation coefficients between RS and the triaxial volume calculation, and the triaxial volume calculation and 5-mm volumetry, were generally statistically insignificant.
Conclusions: Expected SRF was estimated more accurately by CT volumetric calculations (especially 5-mm slice-based volumetry) than RS.