Introduction: Despite the rise of micro-invasive glaucoma surgery (MIGS), glaucoma drainage device implantation continues to be a mainstay among glaucoma surgical treatment options. Anterior chamber tube placement, while effective in reducing intraocular pressure (IOP), poses corneal endothelial risks. Ciliary sulcus tube placement shows promise in reduced corneal endothelial cell loss, but proper sulcus placement can be challenging. Our study describes the initial safety and effectiveness results using  a novel sulcus tube internal needle guidewire (STING) technique for glaucoma drainage device insertion into the ciliary sulcus.

Methods: We retrospectively reviewed the charts of all consecutive patients who underwent the STING technique using the Ahmed ClearPath, Ahmed Glaucoma Valve, or Baerveldt glaucoma implant with at least 6 months of follow-up. Demographic characteristics, type of glaucoma, previous medical and surgical treatment, pre- and postoperative IOP, pre- and postoperative medications, complications, and success rates were recorded.

Results: Out of nine eyes, seven resulted in qualified success (77.8%). Preoperative mean IOP was 23.8 ± 6.3 mmHg, and postoperative IOP decreased significantly to 14.9 ± 3.7 mmHg (p = 0.008). The average number of preoperative medications per patient was 4.4 ± 0.7, while the average number of postoperative medications per patient was reduced significantly to 3.6 ± 1.0 (p = 0.039).

Conclusion: The STING technique is a novel method for placing a glaucoma drainage device into the ciliary sulcus, leading to IOP lowering with minimal complications. The STING technique is designed to improve surgical ease and increase anatomical precision of sulcus tube placement. Video available for this article.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10787709PMC
http://dx.doi.org/10.1007/s40123-023-00848-0DOI Listing

Publication Analysis

Top Keywords

sulcus tube
16
glaucoma drainage
16
drainage device
16
sting technique
16
tube placement
12
glaucoma
9
tube internal
8
internal needle
8
needle guidewire
8
technique glaucoma
8

Similar Publications

We report three cases demonstrating the efficacy and versatility of the micro-incision scleral tunnel (MIST) technique, a novel method for Ahmed glaucoma valve (AGV) tube insertion. MIST is characterized by its small incision, sutureless approach, anterior-to-posterior tunnel creation, and allograft-free design. The technique involves creating a scleral tunnel using a 1-mm crescent knife (Bleb Knife II), allowing for secure tube placement into the anterior chamber, ciliary sulcus, or vitreous cavity.

View Article and Find Full Text PDF

Objective Of Surgery: The aim of this surgical technique is the implantation of a glaucoma drainage device (GDD) in eyes with aphakic glaucoma following injector-assisted implantation of an artificial iris into the ciliary sulcus.

Indications: This atraumatic tube insertion technique can be performed during GDD implantation after implantation of an artificial iris into the ciliary sulcus.

Surgical Technique: Following injector-assisted implantation of an artificial iris into the ciliary sulcus of eyes, the iris can shift into the chamber angle.

View Article and Find Full Text PDF

Purpose: This report describes a surgical approach involving a 5-layer closure performed for a patient with uveitic glaucoma who had an Ahmed Glaucoma Valve placed 12 years prior to presentation, then erosions which were revised 2 and 4 years ago. Additionally, the patient had a Descemet Stripping Endothelial Keratoplasty (DSEK) completed 4 years prior to presentation. The patient presented with a tube that was eroded and a DSEK that had failed.

View Article and Find Full Text PDF

Objective: To investigate the outcomes of aqueous shunt exposure repair and to identify risk factors for recurrent exposure after surgical repair.

Methods: This is a retrospective interventional case series of consecutive patients who underwent repair of an exposed aqueous shunt. Demographic and clinical data were extracted from the patients' records and survival analysis was employed to determine the probability of survival of the repair without further exposure.

View Article and Find Full Text PDF

In this study, we validated the new technique for inserting the tube of the Ahmed glaucoma valve (AGV) into the ciliary sulcus. AGV tube insertion was performed by introducing a 4-0 nylon thread into the anterior chamber from the corneal incision on the opposite side of the AGV. The thread was placed in the lumen of a 23-G needle that was inserted into the sclera and ciliary sulcus from the AGV side.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!