Download full-text PDF

Source

Publication Analysis

Top Keywords

inter- intra-examiner
4
intra-examiner reliability
4
reliability upper
4
upper cervical
4
cervical x-ray
4
x-ray marking
4
marking system
4
inter-
1
reliability
1
upper
1

Similar Publications

Validity and Reliability of Kinovea for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion.

Sensors (Basel)

January 2025

Unidad de Investigación en Fisioterapia, Spin off Centro Clínico OMT-E Fisioterapia SLP, Universidad de Zaragoza, Domingo Miral s/n, 50009 Zaragoza, Spain.

The anatomy of the pelvis may obscure differences in pelvic tilt, potentially underestimating its correlation with clinical measures. Measuring the total sagittal range of pelvic movement can serve as a reliable indicator of pelvic function. This study assessed the inter- and intra-examiner reliability of the Kinovea version 0.

View Article and Find Full Text PDF

To assess the effectiveness of Biodentine (BD), mineral trioxide aggregate (MTA) and ferric sulfate (FS) as pulpotomy agents in primary molars and evaluate the impact of behavior guidance strategies on pulpotomy success. In this retrospective cross-sectional study, data from 374 cases (50.5 percent male, aged two to 10 years) undergoing 469 pulpotomies at a university pediatric clinic between April 1, 2016 and January 1, 2020 were analyzed.

View Article and Find Full Text PDF

Objectives: This study compared the clinical accuracy of two different stationary face scanners, employing progressive capture and multi-view simultaneous capture scanning technologies.

Methods: Forty dentate volunteers participated in the study. Soft tissue landmarks were marked with a pen on the participants' faces to measure the distances between them.

View Article and Find Full Text PDF

Qualitative and quantitative assessment of tooth wear in young individuals.

J Dent

December 2024

Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Electronic address:

Objectives: To assess the degree of tooth wear in children and adolescents by application of a qualitative wear index and by quantitative measurement on digital models. The hypothesis was that the quantitative method would be sensitive to reliably measure tooth wear.

Methods: Existing digital models (n = 24) gathered from a prospective clinical study were analysed.

View Article and Find Full Text PDF

The Schirmer strip measures tear volume in millimeters. A major limitation of the Schirmer strip is that it does not measure tear volume in a volumetric unit. Furthermore, the linearity range, lower limit of detection (LLOD), and lower limit of quantification (LLOQ) are not established.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!