Error estimates in atom coordinates and B factors in macromolecular crystallography.

Curr Res Struct Biol

Department of Chemistry, University of Manchester, M13 9PL, UK.

Published: November 2023

AI Article Synopsis

  • The diffraction precision index (DPI) was introduced by Cruickshank in 1999 to assess the quality of biological macromolecule crystal structures, which has since been expanded to analyze individual atom coordinates.
  • A webserver has been developed that allows users to convert PDB entries to include individual atom coordinate errors calculated using the DPI method, aiding in the evaluation of molecular dynamics and non-covalent distance error estimates.
  • Challenges remain in accurately representing the standard uncertainties of atomic displacement parameters (B factors) in publications, but parallelized workflows for diffraction data processing can improve B factor precision estimation.

Article Abstract

The overall diffraction precision index (DPI) of a biological macromolecule crystal structure was first described by Cruickshank in 1999. This topical review proceeds from this point and describes the subsequent elaboration of the index to individual atom coordinates. Additional developments were introduced by the availability of a webserver, which provides a transformed PDB entry with individual atom coordinate errors derived from applying the DPI method using the parameters provided by the authors and then subsequently added to the PDB file. This webserver has been extensively used and harnessed in describing non-covalent distance error estimates as well as assessing the significance, or otherwise, of atom movements in a variety of studies. The standard uncertainties on a biological macromolecule's atomic displacement parameters (the 'B factors') has been an entirely different challenge but is obviously important since the crystallographic community has developed the habit of quoting B factors to a false precision in papers. This can convey a false certainty in the dynamics of a structure. A method involving parallelisation of workflows for diffraction image data processing does however offer estimates of the precision of B factors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10695842PMC
http://dx.doi.org/10.1016/j.crstbi.2023.100111DOI Listing

Publication Analysis

Top Keywords

error estimates
8
atom coordinates
8
individual atom
8
atom
4
estimates atom
4
coordinates factors
4
factors macromolecular
4
macromolecular crystallography
4
crystallography diffraction
4
diffraction precision
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!