The Effect of Water Coolant and Bur Type on Pulp Temperature When Removing Tooth Structure and Restorative Dental Materials.

Oper Dent

*Paul V. Abbott, BDSc, MDS, DDSc, FRACDS(Endo), emeritus professor, UWA Dental School, The University of Western Australia, Nedlands, WA, Australia.

Published: January 2024

Objective: The aim was to compare intrapulp temperature (IPT) changes when flat-fissure diamond burs and pear-shaped tungsten carbide burs were used to cut tooth structure, amalgam, and composite resin with and without water coolant.

Methods: Thermocouples were inserted into the pulp chamber of extracted intact mandibular molars. The thermocouples were connected to an electronic thermometer that detects temperature every second to an accuracy of 0.1°C. IPT changes were recorded while using a high-speed handpiece during MOD cavity preparations (n=40), composite resin removal (n=40), and amalgam removal (n=40). A two-way ANOVA was used for each procedure to test for the effect of bur (pear-shaped tungsten carbide vs flat-fissured diamond) and water coolant (on vs off), with significant main effects (α=0.05) further analyzed using Tukey's multiple comparison test.

Results: During MOD cavity preparation, water coolant reduced changes in IPT (0.03±0.27°C) compared to no water coolant (1.27±0.29°C) when tungsten carbide burs were used (p<0.05) but not when diamond burs were used. During composite resin removal, tungsten carbide burs had less changes in IPT (0.55±0.18°C) compared to diamond burs (1.66±0.50°C) with no water coolant (p<0.05). Water coolant also reduced changes in IPT (0.09±0.14°C) compared to no water coolant (1.66±0.50°C) when diamond burs were used (p<0.01). Water coolant did not significantly affect IPT when tungsten carbide burs were used. During amalgam removal, tungsten carbide burs had lower changes in IPT (0.56±0.15°C) compared to diamond burs (1.88±0.43°C) with no water coolant (p<0.05). Water coolant also significantly reduced changes in IPT (0.71±0.2°C) compared to no water coolant (1.88±0.43°C) when diamond burs were used (p<0.05) but not when tungsten carbide burs were used.

Conclusions: Water coolant reduced IPT changes when drilling tooth structure with tungsten carbide burs, but not when removing amalgam or composite. Conversely, water coolant reduced IPT changes when drilling with flat fissure diamond burs to remove amalgam and composite, but not when removing tooth structure. When amalgam and composite were removed without water coolant, the tungsten carbide burs resulted in lower IPT changes than when flat fissure diamond burs were used in the same way.

Download full-text PDF

Source
http://dx.doi.org/10.2341/23-033-LDOI Listing

Publication Analysis

Top Keywords

water coolant
16
tungsten carbide
12
tooth structure
8
ipt changes
8
pear-shaped tungsten
8
carbide burs
8
composite resin
8
mod cavity
8
removal n=40
8
water
5

Similar Publications

OpenFlume: An accessible and reproducible benchtop flume for research and education.

HardwareX

December 2024

Brown University, School of Engineering, 184 Hope St, Providence, RI 02912, United States of America.

Open-channel flumes are an important tool in fluid mechanics research and education. However, the few commercially available small-scale flumes are generally expensive and lack complete characterization. In this work, we present an open-source, low-cost, modular benchtop laboratory flume that is designed to be accessible and reproducible.

View Article and Find Full Text PDF

This article investigates the convective thermal and solutal exchange from the active walls of a trapezium chamber which is filled with multi-walled carbon nanotubes (MWCNT)-silicon dioxide (SiO)-ethylene glycol-water hybrid nano-coolant. The hybrid nano-coolant exhibits non-Newtonian shear-thinning rheology and is modeled by the power-law viscosity as per an exploratory report. The convection is generated by both the thermal and solutal buoyancy forces in the presence of a magnetic field.

View Article and Find Full Text PDF

Several modifications have been made to the radiator's dimensions and materials as part of the evolution of the automotive cooling cycle. Coolant is an important factor that greatly affects the efficiency of the cooling cycle. In applications involving heat transmission, nanofluids have become a viable possibility coolant.

View Article and Find Full Text PDF

The fuel cell vehicle is one of the essential directions for developing new energy vehicles. But heat dissipation is a critical technical difficulty that needs to be solved urgently. Nano-coolant is a promising coolant that can potentially replace the existing coolant of a fuel cell.

View Article and Find Full Text PDF

Novel high-strength, recyclable, microbial-resistant, and freeze-thaw dual topological network hydrogel cooling media.

Food Chem

February 2025

Department of Pharmaceutical Engineering, College of Food and Bioengineering, Xihua University, Chengdu 610039, China; Sichuan Engineering Research Center for Molecular Targeted Diagnostic & Therapeutic Drugs, Research and Application of Small Organic Chiral Molecules Key Laboratory of Yibin City, Department of Chemistry, Xihua University, Chengdu 610039, China. Electronic address:

The demand for multifunctional hydrogels, offering high mechanical strength, efficient cooling, and antimicrobial properties, is growing in food preservation. Here, a dual-network (DN) hydrogel PM@Cur, which includes curcumin, is fabricated through chemical crosslinking and hydrogen bonding interactions. The resulting hydrogels can withstand more than five freeze-thaw cycles at -80 °C, and resist brittleness after liquid nitrogen treatment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!