A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visual and refractive outcomes after implantation of two models of trifocal intraocular lenses in eyes with previous corneal ablation to treat hyperopia. | LitMetric

Background: To assess whether a trifocal intraocular lens (IOL) with neutral spherical aberration (SA) provides better visual and refractive outcomes than a trifocal IOL with negative SA after hyperopic corneal laser ablation.

Methods: This is a retrospective comparative study. Patients were classified according to the IOL implanted after cataract or clear lens phacoemulsification [group 1, PhysIOL FineVision Pod-F (negative SA); group 2, Rayner RayOne Trifocal (neutral SA)]. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction.

Results: 198 eyes of 119 patients met the inclusion criteria. Group 1 comprised 120 eyes and group 2 comprised 78 eyes. At completion, the refractive and predictability results were significantly better in group 1 than in group 2 for manifest refraction spherical equivalent (MRSE) (P < 0.001). Differences were not significant for UDVA (P = 0.647), CDVA (P = 0.343), UIVA (P = 0.059), UNVA (P = 0.382), binocular UIVA (P = 0.157), or binocular UNVA (P = 0.527). Safety and efficacy indices in refractive lens exchange (RLE) eyes were 0.96 and 0.91, and 0.89 and 0.93 in groups 1 and 2, respectively (P = 0.254 and 0.168). Patient satisfaction was similar in both groups (P > 0.05, all items).

Conclusion: In eyes previously treated with hyperopic corneal ablation, implantation of a trifocal IOL with neutral SA provided better efficacy and safety outcomes but worse predictability outcomes than those obtained with a trifocal model with negative SA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10702098PMC
http://dx.doi.org/10.1186/s40662-023-00366-xDOI Listing

Publication Analysis

Top Keywords

visual acuity
16
visual refractive
8
refractive outcomes
8
trifocal intraocular
8
corneal ablation
8
iol neutral
8
outcomes trifocal
8
trifocal iol
8
hyperopic corneal
8
distance visual
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!