Purpose: To assess the effect of visible femoral shaft length on the accuracy of radiographic landmarks of the medial patellofemoral complex (MPFC).
Methods: In 9 cadaveric knees, the MPFC footprint was exposed on the medial femur, and its proximal and distal boundaries were marked. Lateral fluoroscopic images of the knee were assessed in 1-cm length increments, beginning 1 cm proximal to the medial condyle and continuing proximally to 8 cm. The MPFC midpoint was described on each image relative to the posterior cortical line of the femur and a line perpendicular to this line through the proximal margin of the medial condyle. In addition, the MPFC midpoint was assessed relative to a line from the proximal posterior cortex to the midpoint of Blumensaat line.
Results: Using the posterior cortical line as a reference, the MPFC radiographic landmark moved anteriorly with decreasing visible femoral shaft on radiographs, particularly at 4 cm and less. However, no proximal-distal change was noted. Linear regression analysis demonstrated a relationship between visible femoral shaft and MPFC position on radiographs (R = 0.461, R = 0.212, B = -0.636, P < .001). For every centimeter decrease in the visible femoral shaft, the radiographic MPFC footprint moved anteriorly by 0.636 mm. Receiver operating characteristic curve analysis revealed that a minimum of 4 cm of femoral shaft on lateral radiographs is required for accurate MPFC footprint localization (area under the curve = 0.80; sensitivity = 76.7%; specificity = 69.0%; P < .001). In contrast, no anterior-posterior change was seen when referencing a line from the proximal posterior cortex to the midpoint of Blumensaat line.
Conclusions: When using the posterior cortical line to identify the midpoint of the MPFC, at least 4 cm of femoral shaft should be visible for accurate assessment. If less than 4 cm of shaft is visible, a line through the midpoint of Blumensaat line and the proximal posterior cortex can be used as an alternative method to estimate the position of the femoral footprint.
Clinical Relevance: As fluoroscopy is frequently used intraoperatively for MPFC reconstruction, our findings may serve as a guide when assessing femoral tunnel placement on fluoroscopy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2023.11.025 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", 80131 Naples, Italy.
The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners.
View Article and Find Full Text PDFAnimals (Basel)
January 2025
Department of Biomedical Sciences, Ross University School of Veterinary Medicine, Basseterre P.O. Box 334, Saint Kitts and Nevis.
The paper presents a detailed gross anatomical description of the elements of the pelvic limb in the African green monkey and provides comparative and differential elements on pelvic limb monkey osteology. The osteometric investigation adds value to the gross morphological and radiological investigation, adjoining metric data to the gross descriptive data set. The main methodology used was the gross morphological investigation, doubled by regular osteometrical and radiographical assessments.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Department of Trauma Surgery, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.
Purpose: The aim of this study was to evaluate the feasibility of using patient-specific implants (PSI) for complex shaft corrective osteotomies in multiplanar deformities of long bones in the lower extremities. Additionally, it aimed to investigate the added value of these implants by quantifying surgical accuracy on postoperative CT, comparing their outcomes to two commonly used techniques: 3D virtual visualizations and 3D-printed surgical guides.
Methods: Six tibial and femoral shaft corrective osteotomies were planned and performed on three Thiel embalmed human specimen.
J Anat
January 2025
Department of Orthopedics, Affiliated Zhongshan Hospital of Dalian University, Dalian, China.
The primary weight-bearing structure of the proximal femur, trabecular bone, has a complex three-dimensional architecture that was previously difficult to comprehensively display. This study examined the spatial architecture of trabecular struts in the coronal, sagittal, and horizontal sections of the proximal femur using 21 cases prepared with P45 sectional plasticization. The primary compressive strut (PCS) exhibited a "mushroom-like" shape with upper and lower parts.
View Article and Find Full Text PDFActa Radiol
January 2025
Department of Orthopedics and Experimental and Clinical Medicine, Faculty of Health Science, Linköping University, Linköping, Sweden.
Background: Bisphosphonate-associated stress fractures, atypical femur fractures (AFF), are a rare subgroup of femoral stress fractures. Their correct and early diagnosis is imperative for appropriate treatment.
Purpose: To investigate the sensitivity of written radiology reports to mention radiographic features of AFF, depending on the time period and academic level of the hospital.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!