Purpose: A high transfer accuracy of the intraoral implant position to a model is required, to manufacture implant-supported restorations. However, clinically relevant deviations persist between the intraoral implant position and the model obtained, even for the benchmark conventional custom implant impressions with polyether. Thus, new approaches using 3-D printed impression trays may increase the transfer accuracy of implant impressions. The ability to adjust parameters such as the thickness of the layers and the influence of the openings in the impression tray could potentially affect accuracy.

Methods: Four different types of impression trays (n = 10 for each group) for the conventional impression technique were investigated: conventional custom impression tray, customized foil tray, chairside 3-D printed impression tray with the SHERA system, and the Primeprint system using an implant master model with four implants in the posterior region and a reference cube. After plaster model casting, all models were measured using a coordinate measuring machine, and the deviation from the reference dataset was determined. A statistical ANOVA analysis was performed (p < 0.05).

Results: Chairside 3-D printed impression trays showed the best results, followed by conventional custom impression trays. Implant impressions obtained using a customized foil tray exhibited the lowest accuracy. Statistically significant differences were observed between 3-D printed impression trays and conventional custom impression and customized foil trays (p < 0.05). Whereas, the implant position did not have any significant influence on accuracy (p > 0.05).

Conclusions: Chairside 3-D printed impression trays significantly increase the transfer accuracy for implant impression taking.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10697909PMC
http://dx.doi.org/10.1186/s40729-023-00516-9DOI Listing

Publication Analysis

Top Keywords

3-d printed
12
printed impression
12
impression trays
12
impression tray
12
chairside 3-d
8
impression
8
transfer accuracy
8
intraoral implant
8
implant position
8
position model
8

Similar Publications

Deep learning-based defect detection in film-coated tablets using a convolutional neural network.

Int J Pharm

January 2025

Process Research & Development, Merck & Co., Inc., Rahway, NJ, USA.

Film-coating is a critical step in pharmaceutical manufacturing. Traditional visual inspections for film-coated tablet defect assessment are subjective, inefficient, and labor-intensive. We propose a novel approach utilizing machine learning and image analysis to address these limitations.

View Article and Find Full Text PDF

Comparison of Methods of Eliciting Vital Capacity: Forced Versus Slow Vital Capacity.

J Voice

January 2025

Department of Statistics, Purdue University, Mathematical Sciences Building, 150 N. University Street, Room 231, West Lafayette, IN 47907.

Background: Methods to elicit the vital capacity (VC) include forced vital capacity (FVC) and slow vital capacity (SVC). Because the FVC maneuver can be affected by air trapping or inefficiencies in lung emptying vs. the SVC, the SVC-FVC difference may be substantial and diagnostically meaningful in elderly individuals and patients with respiratory obstruction.

View Article and Find Full Text PDF

The effect of the guide hole height on the accuracy of implant placement: An in-vitro study.

J Stomatol Oral Maxillofac Surg

January 2025

School of Dentistry, Chonnam National University, Gwangju, Republic of Korea; Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea. Electronic address:

Objective: Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.

Materials And Methods: Ten maxillary models with edentulous areas were created using CT and optical scan data.

View Article and Find Full Text PDF

The treatment of acetabular defects in revision arthroplasty is an increasing challenge. Different classifications have been introduced for preoperative planning to achieve the best possible result. 3D printing is a way to better visualize and understand these defects.

View Article and Find Full Text PDF

In short-range microwave imaging, the collection of data in real environments for the purpose of developing techniques for target detection is very cumbersome. Simultaneously, to develop effective and efficient AI/ML-based techniques for target detection, a sufficiently large dataset is required. Therefore, to complement labor-intensive and tedious experimental data collected in a real cluttered environment, synthetic data generation via cost-efficient electromagnetic wave propagation simulations is explored in this article.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!