AI Article Synopsis

  • The study investigates whether using barrier dressings during cardiac device surgeries can reduce infection risk by limiting contamination from skin flora.
  • The BARRIER-PROTECT trial is a double-blinded, randomized controlled study involving patients who are undergoing repeat procedures on the same device site.
  • The primary measure is to see if the barrier dressing impacts the positivity of pocket swab cultures post-surgery, potentially indicating a lower risk of infections related to cardiac implantable electronic devices.

Article Abstract

Background: Cardiac implantable electronic device (CIED) procedures can be associated with serious complications, including infection with significant mortality and morbidity, necessitating removal of the device and prolonged hospitalization. One potential pathophysiological mechanism is pocket contamination at the time of device implantation. Therefore, steps taken to prevent contamination at this stage can potentially reduce CIED infections.The barrier dressing, an adhesive material applied to the skin, has the potential to reduce the colonization of the surgical site with host flora that can predispose to infection. There are a limited number of randomized prospective studies on barrier dressing use during various surgeries, but it has never been systematically studied in CIED implantation.

Objectives: Do Barrier Dressings Reduce Cardiac Implantable Device Infection? (BARRIER-PROTECT trial; NCT04591366) is a single-centre, prospective, double-armed, single-blinded, randomized controlled trial designed to evaluate the use of an intra-operative adhesive barrier dressing to reduce the risk of end-of-procedure pocket swab positivity. We hypothesize that adhesive draping during implant procedures will reduce the risk of contamination from the skin flora. Also, we aim to investigate if the end-of-procedure pocket swab culture positivity can be used as a potential surrogate marker of CIED infection.

Methods And Design: Patients undergoing a second or later procedure on the same device pocket (pulse generator change, lead/pocket revision or upgrade) will be enrolled. Eligible and consenting patients will be equally randomized to the use of barrier dressing or not using an automated web-based system. Patients, but not the operator, will be blinded to the arm. The person performing the pocket swabs will also be blinded. The primary endpoint is the end-of-procedure pocket swab culture positivity. The main secondary endpoint is the CIED infection rate.

Discussion: This is the first randomized controlled trial to assess the effectiveness of using a barrier adhesive draping on reducing the end-of-procedure pocket swab culture positivity. In this study, we are exploring a low-cost intervention that may significantly reduce CIED infection. Also, having a valid surrogate marker for CIED infection at the time of implant will facilitate design of future clinical trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10686845PMC
http://dx.doi.org/10.1016/j.heliyon.2023.e22229DOI Listing

Publication Analysis

Top Keywords

barrier dressing
16
end-of-procedure pocket
16
pocket swab
16
cardiac implantable
12
randomized controlled
12
controlled trial
12
swab culture
12
culture positivity
12
cied infection
12
barrier dressings
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!