Objective: To determine the effects of using either a linear or curvilinear oscillating, battery-powered saw blade on the extent of bone resection, bone fissure or fragmentation, soft tissue trauma, and surgical time for femoral head and neck excision (FHNE) in feline cadavers.
Animals: 18 feline cadavers.
Methods: Paired feline cadaveric femora were randomly assigned to either a 10 mm linear or 12 mm curvilinear blade for FHNE by 2 surgical residents. CT of each femur pre- and postoperatively were used to create 3D reconstructions of each femur. The residual remaining or excessively resected bone volume at the ostectomy site was compared to an "ideal" ostectomy line made by a board-certified surgeon on preoperative CTs.
Results: There were no significant differences in residual or excessive bone resection by a saw blade (P = .84), between surgeons (P = .65), or in surgery time (P = .39). When compared to the "ideal" ostectomy, the linear saw blade removed slightly less bone compared to the curvilinear blade, but was not statistically significant (P = .82). No fissures or fractures were noted; however, the curvilinear blade removed the entire lesser trochanter in 1 cadaver and the linear blade partially removed the greater trochanter in 1 femur and 2 lesser trochanters in 2 femora.
Clinical Relevance: The use of a curvilinear blade may be a viable option for performing FHNE in cats. In vivo studies are warranted to determine its efficacy in clinical cases where FHNE is performed and the incidence of complications postoperatively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/ajvr.23.08.0187 | DOI Listing |
Am J Vet Res
December 2023
Veterinary Specialist Services, Queensland, Australia.
Objective: To determine the effects of using either a linear or curvilinear oscillating, battery-powered saw blade on the extent of bone resection, bone fissure or fragmentation, soft tissue trauma, and surgical time for femoral head and neck excision (FHNE) in feline cadavers.
Animals: 18 feline cadavers.
Methods: Paired feline cadaveric femora were randomly assigned to either a 10 mm linear or 12 mm curvilinear blade for FHNE by 2 surgical residents.
Heliyon
November 2022
College of Mechanical Engineering, Hubei University of Technology, Wuhan, China.
Sweep rotor blade would reduce blade fatigue load, but induce additional blade root torsional moment. This paper introduces pre-bend/sweep blade to reduce this additional torsional moment. A parameterized mathematical model is developed to define the geometrical configuration of pre-bend/sweep blade with a fully curvilinear axis based on the curves theory of differential geometry.
View Article and Find Full Text PDFActa Cir Bras
August 2019
PhD, Associate Professor, Postgraduate Program in Health Sciences, Department of Surgery , FM - UFG , Goiania - GO , Brazil . Technical procedures, intellectual and scientific content of the study, critical revision.
Purpose: To analyze the resistance to medial traction of abdominal wall muscles, before and after performing relaxing incisions.
Methods: Seventeen live pigs were used. After a median laparotomy, the handles were made in the rectus abdominis muscles (RAM) to fit the dynamometer.
Indian J Ophthalmol
July 2018
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
We describe our technique for the management of late-onset liquefied after-cataract (LAC) to ensure long-term visual axis clarity. The densely adherent anterior capsular rim over the intraocular lens (IOL) optic was released with the help of microvitreoretinal blade, and multiple relaxing radial incisions were made on the capsular rim to facilitate easy access to the capsular bag. A thorough capsular bag lavage was performed with the help of bimanual irrigation-aspiration.
View Article and Find Full Text PDFI present several classes of analytical and semi-analytical solutions for the design of high-speed rotary optical delay lines that use a combination of stationary and rotating curvilinear reflectors. Detailed analysis of four distinct classes of optical delay lines is presented. Particularly, I consider delay lines based on a single rotating reflector, a single rotating reflector and a single stationary reflector, two rotating reflectors, and two rotating reflectors and a single stationary reflector.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!