Since the reported Sellmeier equation of water is fitted with sparse sampling points in the near-infrared region, the simulated refractive index sensitivity of dispersion enhanced interferometers deviates from the true value. Here, we measure the refractive index of aqueous sample based on hyperspectra, and research the effect of dispersion on ultra-sensitive interferometer. A piece of quartz plate is used to generate hyperspectra in the near-infrared region by building a wavefront splitting fiber Mach-Zehnder interferometer (WFSF-MZIs). The refractive index of saline water is tested after measuring the thickness of the quartz plate. By taking the wavelength of 1450 nm as break-point, the empirical dispersion equations of saline water are piecewise fitted. When the normal and abnormal dispersion are taken into account, the theoretical sensitivity of phase compensated WFSF-MZI is in good agreement with the experimental results. Our methodology provides a good reference in designing dispersion sensitized optical refractive index sensor for detecting aqueous samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.504279 | DOI Listing |
Laser-deflection-based acoustic sensing is known for high bandwidth but low sensitivity. By embedding the sensing laser within a Sagnac interferometer and incorporating split-beam detection-originally developed for optical trapping microscopy-we demonstrate sensitive acoustic detection in air with a 2 MHz bandwidth. In a direct comparison, our method far-exceeds performance metrics of a state-of-the-art, commercially-available, high-bandwidth microphone.
View Article and Find Full Text PDFA tapered thin-diameter photonic crystal fiber interferometer (TTD-PCFI) biosensor is proposed and demonstrated for DNA hybridization detection with an ultra-low limit of detection (LoD) and high specificity. The TTD-PCFI is fabricated by arc-discharged melting and adiabatic tapering, with a lower loss and stronger evanescent optical field. The fabricated TTD-PCFI with a diameter of 8.
View Article and Find Full Text PDFSince the reported Sellmeier equation of water is fitted with sparse sampling points in the near-infrared region, the simulated refractive index sensitivity of dispersion enhanced interferometers deviates from the true value. Here, we measure the refractive index of aqueous sample based on hyperspectra, and research the effect of dispersion on ultra-sensitive interferometer. A piece of quartz plate is used to generate hyperspectra in the near-infrared region by building a wavefront splitting fiber Mach-Zehnder interferometer (WFSF-MZIs).
View Article and Find Full Text PDFAn ultra-sensitive sensor, based on two Fabry-Perot interferometers (FPIs), has been realized for temperature and pressure sensing. A polydimethylsiloxane (PDMS)-based FPI was used as a sensing cavity, and a closed capillary-based FPI was used as a reference cavity for its insensitivity to both temperature and pressure. The two FPIs were connected in series to obtain a cascaded FPIs sensor, showing a clear spectral envelope.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!