An international collaborative study was run within the framework of the Biological Standardisation Programme (BSP) of the Council of Europe and the Commission of the European Union to establish replacement batches for European Pharmacopoeia (Ph. Eur.) Heparin Low-Molecular-Mass (LMM) for calibration Chemical Reference Substance batch 3 (CRS3) used for the characterisation of LMM heparins by high performance size-exclusion chromatography. Two candidate batches (A, cCRS4 and B, cCRS5) were filled using the same material as the existing official calibrants, adopted with either an assigned number-average molecular mass (Mna) or a broad standard table (BST). Fifteen laboratories evaluated the suitability of these candidate batches for use as calibrants with the pharmacopoeial dual refractive index/ultraviolet (RI/UV) detector calibration method, as well as with a modified mobile phase and the BST calibration method. Seven preparations of LMM heparin were tested. The results confirmed that the proposed batches are suitable for use with the same characteristic Mna as CRS3 and with the BST established for the World Health Organization (WHO) 2 International Standard (IS). The BST calibration method gave comparable results to the RI/UV method, while showing better reproducibility, being easier to perform and requiring no calibrant with UV absorbance. The modified mobile phase had no impact on the calculated values while improving separation between the calibrant and salt peaks. The two candidate batches were adopted as Ph. Eur. Heparin LMM for calibration CRS batches 4 and 5, respectively, with the assigned Mna value of 3800 and a BST. In anticipation of the depletion of the calibrant required for use with the RI/UV method, and taking into account the unlikely procurement of a new lot of suitable starting material, it was recommended to include the BST method in Ph. Eur. monograph . In order to improve peak separation, it was also recommended to include the use of ammonium acetate solution as mobile phase in the monograph, both for the Ph. Eur. RI/UV and the proposed BST calibration methods. Further to this study, Ph. Eur. monograph was revised to replace the RI/UV method by the BST method. This contributed to the harmonisation of methods across regions, thereby facilitating a concerted global action for the development and establishment of the next batches of calibrants for the quality control of LMM heparins.
Download full-text PDF |
Source |
---|
Eur J Clin Pharmacol
January 2025
Department of Obstetrics and Gynaecology, West China Second University Hospital, Sichuan University, No. 20, Renmin South Road, Section 3, Chengdu, 610041, Sichuan Province, China.
Background: The prevalence of conditions necessitating anticoagulation therapy among pregnant women has been steadily increasing. Although low-molecular-weight heparin (LMWH) is commonly used, several studies have investigated the use of fondaparinux in pregnant women. However, the safety profile of fondaparinux in this population remains to be fully elucidated.
View Article and Find Full Text PDFEur J Pharm Sci
January 2025
Department of Ophthalmology, LMU University Hospital, LMU Munich, Munich, Germany. Electronic address:
Adeno-associated virus (AAV)-based vectors have emerged as an effective and widely used technology for somatic gene therapy approaches, including those targeting the retina. A major advantage of the AAV technology is the availability of a large number of serotypes that have either been isolated from nature or produced in the laboratory. These serotypes have different properties in terms of sensitivity to neutralizing antibodies, cellular transduction profile and efficiency.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Internal Department II of Cardiology, Angiology and Internal Intensive Medicine, Ordensklinikum Elisabethinen Linz, Fadingerstraße 1, 4020 Linz, Austria.
Eur J Med Res
December 2024
Department of Clinical Laboratory, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, 17 Yongwai Zhengjie, Nanchang, 330006, Jiangxi, China.
Background: This study aims to evaluate the diagnostic and prognostic value of heparin-binding protein (HBP) in cerebrospinal fluid (CSF) for patients with intracranial infections.
Methods: This study included 211 subjects, of whom 138 were diagnosed with intracranial infections, 20 were patients with non-infectious inflammatory encephalopathies, and 53 controls who were eventually excluded from intracranial infections and inflammatory encephalopathies. The levels of HBP and procalcitonin (PCT) in CSF were detected in the subjects, and the diagnostic value of CSF HBP and PCT for intracranial infections was assessed using the receiver operating characteristic (ROC) curves.
Eur J Cancer
January 2025
Department of Dermatology and Venereology, University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany; Fleur Hiege Center for Skin Cancer Research, University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany. Electronic address:
Background: Cancer immunotherapy has revolutionized melanoma treatment, but the high number of non-responders still emphasizes the need for improvement of therapy. One potential avenue for enhancing anti-tumor treatment is through the modulation of coagulation and platelet activity. Both have been found to play an important role in the tumor microenvironment, tumor growth and metastasis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!