Micro-computed X-ray tomography (μCT) is a volumetric imaging tool used to quantify the internal structure of materials. μCT imaging with mechanical testing ( μCT) helps visualize strain-induced structural changes and develop structure-property relationships. However, the effects on thermophysical properties of radiation exposure during μCT imaging are seldom addressed, despite potential radiation sensitivity in elastomers. This work quantifies the radiation dosage effect on thermo-, chemical-, and mechanical-properties for a vinyl nitrile-based foam. Material properties were measured after (0, 1, 2, and 3) days at (8.1 ± 0.9) kGy/d. Morphological characteristics were investigated via scanning electron microscopy. Thermal transitions were assessed using differential scanning calorimetry. Viscoelasticity was measured with dynamic mechanical analysis over a range from -30 °C to 60 °C. Higher dose lead to stiffening and increased dissipation. Chemical structure was assessed with Fourier transform infrared spectroscopy and energy-dispersive X-ray spectroscopy. Soxhlet extraction was used to measure gel content. In summary, substantial changes occur in thermophysical properties, which may confound structure-property measurements. However, this also provides a modification pathway. Quantitation and calibration of the properties changes informed a finite element user material for material designers to explore tunablity and design optimization for impact protection engineers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10688219PMC
http://dx.doi.org/10.1016/j.matdes.2023.112381DOI Listing

Publication Analysis

Top Keywords

micro-computed x-ray
8
μct imaging
8
thermophysical properties
8
unintended consequences
4
consequences assessing
4
assessing thermo-mechanical
4
changes
4
thermo-mechanical changes
4
changes vinyl
4
vinyl nitrile
4

Similar Publications

Hydroxyapatite Chitosan Gradient Pore Scaffold Activates Oxidative Phosphorylation Pathway to Induce Bone Formation.

Front Biosci (Landmark Ed)

January 2025

Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Fujian Medical University, Fujian Provincial Key Laboratory of Stomatology, National Regional Medical Center, Binhai Campus of The First Affiliated Hospital, 350005 Fuzhou, Fujian, China.

Background: In this study, we prepared a porous gradient scaffold with hydroxyapatite microtubules (HAMT) and chitosan (CHS) and investigated osteogenesis induced by these scaffolds.

Methods: The arrangement of wax balls in the mold can control the size and distribution of the pores of the scaffold, and form an interconnected gradient pore structure. The scaffolds were systematically evaluated and for biocompatibility, biological activity, and regulatory mechanisms.

View Article and Find Full Text PDF

This paper investigates the effects of particle morphology (PM) and particle size distribution (PSD) on the micro-macro mechanical behaviours of granular soils through a novel X-ray micro-computed tomography (μCT)-based discrete element method (DEM) technique. This technique contains the grain-scale property extraction by the X-ray μCT, DEM parameter calibration by the one-to-one mapping technique, and the massive derivative DEM simulations. In total, 25 DEM samples were generated with a consideration of six PSDs and four PMs.

View Article and Find Full Text PDF

: Autologous bone grafting is the first choice for reconstructive surgery in bone defects due to trauma or malignant tumors. However, there is an increasing demand for minimally invasive alternatives involving bone regeneration using artificial materials. Biomimetic materials that replicate the body's microscopic structure, such as Cellnest, are gaining attention.

View Article and Find Full Text PDF

Purpose: To make micro-CT comparison and evaluation of sealant penetration depth in different types of fissures after heating of the material or application of vibrations.

Materials And Methods: One hundred sound third molars have been sealed as follows: group 1 (n = 20), light-cured resin sealant at room temperature, group 2 (n = 20), light-cured resin sealant, preheated to 41.0°C, group 3 (n = 20), light-cured resin sealant, preheated to 51.

View Article and Find Full Text PDF

Enhanced analysis of cellulose nanofibril film structure.

Carbohydr Polym

March 2025

Bioresource Processing Research Institute of Australia, Department of Chemical and Biological Engineering, Monash University, Clayton, VIC 3800, Australia. Electronic address:

Structural analysis of cellulose nanofibril (CNF) films remains challenging due to the stochastic assembly of fibres and presence of nanopores. This limits our ability to link the film structures to their properties, restricting their commercial use. While X-ray micro-computed tomography (μCT) is a powerful technique to map the structure of traditional and commercial paper, there has been limited success in its application for CNF films due to the poor contrast between pores and material, making the reconstructed images difficult to segment and analyse.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!