An all-optical non-resonant photoacoustic spectroscopy system for multicomponent gas detection based on a silicon cantilever optical microphone (SCOM) and an aseismic photoacoustic cell is proposed and demonstrated. The SCOM has a high sensitivity of over 96.25 rad/Pa with sensitivity fluctuation less than ± 1.56 dB between 5 Hz and 250 Hz. Besides, the minimal detectable pressure (MDP) of the sensor is 0.55 μPa·Hz at 200 Hz, which indicates that the fabricated sensor has high sensitivity and low noise level. Six different gases of CO, CO, CH, CH, CH, CH are detected at the frequency of 10 Hz, whose detection limits (3) are 62.66 ppb, 929.11 ppb, 1494.97 ppb, 212.94 ppb, 1153.36 ppb and 417.61 ppb, respectively. The system achieves high sensitivity and low detection limits for trace gas detection. In addition, the system exhibits seismic performance with suppressing vibration noise by 4.5 times, and achieves long-term stable operation. The proposed non-resonant all-optical PAS multi-component gas detection system exhibits the advantages of anti-vibration performance, low gas consumption and long term stability, which provides a solution for working in complex environments with inherently safe.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10682669 | PMC |
http://dx.doi.org/10.1016/j.pacs.2023.100571 | DOI Listing |
Sci Rep
January 2025
Department of Physics, Shiraz university of technology, Shiraz, Iran.
A novel helically twisted photonic crystal fiber (PCF) is designed and proposed for sensing toxic gases with refractive indices ranging from 1.00 to 1.08.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Military Traffic Injury Prevention and Control, Daping Hospital, Army Medical University, No. 10 Changjiang Branch Road, Yuzhong District, Chongqing, 400042, China.
The incidence of blast injuries has been rising globally, particularly affecting the lungs due to their vulnerability. Primary blast lung injury (PBLI) is associated with high morbidity and mortality rates, while early diagnostic methods are limited. With advancements in medical technology, and portable handheld ultrasound devices, the efficacy of ultrasound in detecting occult lung injuries early remains unclear.
View Article and Find Full Text PDFEnviron Sci Technol
January 2025
State Key Laboratory of Heavy Oil Processing, Key Laboratory of Optical Detection Technology for Oil and Gas, College of Science, China University of Petroleum, Beijing 102249, PR China.
The purification efficiency of autoexhaust carbon strongly depends on the heterogeneous interface structure between active metal and oxide, which can modulate the local electronic structure of defect sites to promote the activation of reactant molecules. Herein, the high-dispersion CuO clusters supported on the well-defined CeO nanorods were prepared using the complex deposition slow method. The formation of heteroatomic Cu-O-Ce interfacial structural units as active sites can capture electrons to achieve activation of the NO and O molecules.
View Article and Find Full Text PDFRes Social Adm Pharm
January 2025
University of Iowa College of Pharmacy 342 CPB, Iowa City, IA, 52242, USA. Electronic address:
Background: Point-of-care testing (POCT) is a valuable diagnostic approach for identifying pathogens such as Group A Streptococcus (GAS) and influenza. Early detection through POCT allows for timely initiation of appropriate treatments improving public health outcomes and minimizing antibiotic misuse. Community pharmacists are well positioned to offer POCT and treatment, but they face significant system level barriers to widespread implementation and reach.
View Article and Find Full Text PDFSci Total Environ
January 2025
Université Paris Cité - Institut de Physique du globe de Paris, CNRS, F75005 Paris, France.
Nanoparticles (NPs) exhibit high reactivity and mobility in the environment, and a significant capacity to penetrate living organisms, potentially leading to harmful effects. Volcanoes are the second major source of natural NPs emitted into the atmosphere, with an estimated flux of 342 Tg/year. Few studies have focused on their fate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!