A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Deep learning-based attenuation correction method in Tc-GSA SPECT/CT hepatic imaging: a phantom study. | LitMetric

Deep learning-based attenuation correction method in Tc-GSA SPECT/CT hepatic imaging: a phantom study.

Radiol Phys Technol

Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1 Shikata-Cho, Kita-Ku, Okayama-shi, Okayama, 700-8558, Japan.

Published: March 2024

This study aimed to evaluate a deep learning-based attenuation correction (AC) method to generate pseudo-computed tomography (CT) images from non-AC single-photon emission computed tomography images (SPECT) for AC in Tc-galactosyl human albumin diethylenetriamine pentaacetic acid (GSA) scintigraphy and to reduce patient dosage. A cycle-consistent generative network (CycleGAN) model was used to generate pseudo-CT images. The training datasets comprised approximately 850 liver phantom images obtained from SPECT and real CT images. The training datasets were then input to CycleGAN, and pseudo-CT images were output. SPECT images with real-time CT attenuation correction (SPECT) and pseudo-CT attenuation correction (SPECT) were acquired. The difference in liver volume between real CT and pseudo-CT images was evaluated. Total counts and uniformity were then used to evaluate the effects of AC. Additionally, the similarity coefficients of SPECT and SPECT were assessed using a structural similarity (SSIM) index. The pseudo-CT images produced a lower liver volume than the real CT images. SPECT exhibited a higher total count than SPECT and SPECT, which were approximately 60% and 7% lower, respectively. The uniformities of SPECT and SPECT were better than those of SPECT. The mean SSIM value for SPECT and SPECT was 0.97. We proposed a deep learning-based AC approach to generate pseudo-CT images from SPECT images in Tc-GSA scintigraphy. SPECT with AC using pseudo-CT images was similar to SPECT, demonstrating the possibility of SPECT/CT examination with reduced exposure to radiation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-023-00762-xDOI Listing

Publication Analysis

Top Keywords

pseudo-ct images
24
images spect
20
spect
18
attenuation correction
16
spect spect
16
images
13
deep learning-based
12
learning-based attenuation
8
correction method
8
tomography images
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!